Search
Filters
Close

Celebrate World Corrosion Awareness Day with 20% off eCourses and eBooks with code WCAD2024 at checkout!

NACE SP0216-2016, “Sacrificial Cathodic Protection of Reinforcing Steel in Atmospherically Exposed Concrete Structures.”

HISTORICAL DOCUMENT. Guidelines for sacrificial (galvanic) cathodic protection (SACP) of reinforcing steel in atmospherically exposed concrete elements or structures. Not applicable to nonferrous, coated or galvanized reinforcement.

Product Number: 21403-SG
Publication Date: 2016
$179.00
$179.00
$179.00

Or

HOSTORICAL DOCUMENT. NEW in 2016! This NACE International standard practice presents guidelines for sacrificial (galvanic) cathodic protection (SACP) of reinforcing steel in atmospherically exposed concrete elements or structures. These guidelines intended for owners, engineers, architects and contractors, and those concerned with mitigation of reinforced concrete corrosion through the application of SACP systems. The information in this standard as it relates to SACP systems is intended for atmospherically exposed concrete structures and is not applicable to concrete with nonferrous reinforcement, epoxy-coated, galvanized, or other types of coated reinforcement. SACP applications applied to buried and submerged reinforced concrete structures are not addressed in this standard. Key words: atmospherically exposed concrete, cathodic protection, corrosion, electrical continuity, galvanic, instant-off potential, NACE Publication 01105, polarization, reference electrode, reinforced concrete, SACP, sacrificial cathodic protection, TG 047

HOSTORICAL DOCUMENT. NEW in 2016! This NACE International standard practice presents guidelines for sacrificial (galvanic) cathodic protection (SACP) of reinforcing steel in atmospherically exposed concrete elements or structures. These guidelines intended for owners, engineers, architects and contractors, and those concerned with mitigation of reinforced concrete corrosion through the application of SACP systems. The information in this standard as it relates to SACP systems is intended for atmospherically exposed concrete structures and is not applicable to concrete with nonferrous reinforcement, epoxy-coated, galvanized, or other types of coated reinforcement. SACP applications applied to buried and submerged reinforced concrete structures are not addressed in this standard. Key words: atmospherically exposed concrete, cathodic protection, corrosion, electrical continuity, galvanic, instant-off potential, NACE Publication 01105, polarization, reference electrode, reinforced concrete, SACP, sacrificial cathodic protection, TG 047

Also Purchased