Search
Filters
Close

Celebrate World Corrosion Awareness Day with 20% off eCourses and eBooks with code WCAD2024 at checkout!

Long-Term Performance of HLP Solution for Mildly Sour HIC Testing

Applicability of High Strength Line Pipe solution has been evaluated by conducting 30-day Hydrogen Induced Cracking (HIC) tests. Reproducibility of corrosion loss and HIC damage was investigated in comparison with those of the conventional solution, specified by NACE TM0284-2016, Solution C.

Product Number: 51317--9129-SG
ISBN: 9129 2017 CP
Author: Daisuke Mizuno
Publication Date: 2017
$0.00
$20.00
$20.00

Hydrogen Induced Cracking (HIC) is a major issue of line pipes exposed to sour environments. High Strength Line Pipe (HLP) Committee of The Iron and Steel Institute of Japan (ISIJ) has investigated Fitness for Purpose (FFP) HIC evaluation method and proposed the 0.93N (CH3COOH+CH3COONa) solution. It was reported that the proposed test solution provided excellent pH stability during HIC test in comparison with the conventional EFC16 solution (0.05N CH3COONa) in our previous papers.In this study long-term performance of the HLP solution was investigated. One month HIC test using the HLP solution and conventional test solution was employed to compare pH stability. Frequent pH readjustment during HIC test is not required when the proposed 0.93N acetate solution is used. Corrosion rate and corrosion morphology were investigated to clarify the influence of high acetate concentration in the HLP solution. Advantage of the proposed solution in practical use condition will be presented and discussed in this paper.

HIC, line pipe, HLP, fit-for-purpose

Hydrogen Induced Cracking (HIC) is a major issue of line pipes exposed to sour environments. High Strength Line Pipe (HLP) Committee of The Iron and Steel Institute of Japan (ISIJ) has investigated Fitness for Purpose (FFP) HIC evaluation method and proposed the 0.93N (CH3COOH+CH3COONa) solution. It was reported that the proposed test solution provided excellent pH stability during HIC test in comparison with the conventional EFC16 solution (0.05N CH3COONa) in our previous papers.In this study long-term performance of the HLP solution was investigated. One month HIC test using the HLP solution and conventional test solution was employed to compare pH stability. Frequent pH readjustment during HIC test is not required when the proposed 0.93N acetate solution is used. Corrosion rate and corrosion morphology were investigated to clarify the influence of high acetate concentration in the HLP solution. Advantage of the proposed solution in practical use condition will be presented and discussed in this paper.

HIC, line pipe, HLP, fit-for-purpose

Product tags
Also Purchased
Picture for 11107 Effect of Residual Stresses on the HIC Resistance of ERW Pipes and Line Pipe Applications
Available for download

11107 Effect of Residual Stresses on the HIC Resistance of ERW Pipes and Line Pipe Applications

Product Number: 51300-11107-SG
ISBN: 11107 2011 CP
Author: J. Kraegeloh, C. Bosch, H. Brauer, A. Kulgemeyer
Publication Date: 2011
$20.00
Picture for HIC Resistance of Heritage Pipelines Exposed to Mildly Sour Environments
Available for download

51313-02630-HIC Resistance of Heritage Pipelines Exposed to Mildly Sour Environments

Product Number: 51313-02630-SG
ISBN: 02630 2013 CP
Author: Viviane Smith
Publication Date: 2013
$20.00