The importance of moisture testing of concrete floors cannot be stressed enough. Moisture is a leading cause of coatings failures on concrete floors. There are many ways moisture can affect floor coatings on concrete. Moisture testing alone is not sufficient enough at detecting all of the potential problems. Inspecting a building prior to performing any tests will provide a much clearer picture of the potential problems moisture in both liquid and vapor form can pose.
The importance of moisture testing of concrete floors cannot be stressed enough. Moisture is a leading cause of coatings failures on concrete floors. There are many ways moisture can affect floor coatings on concrete. Moisture testing alone is not sufficient enough at detecting all of the potential problems. Inspecting a building prior to performing any tests will provide a much clearer picture of the potential problems moisture in both liquid and vapor form can pose. A moisture survey is a simple tool that will help to identify potential problems not detectable by testing alone. Moisture testing has been described as a snapshot in time. Moisture is a moving target and there is no guarantee that the results achieved one day will be the same the next day. Knowing how moisture can affect a coated floor is essential for testing. Predicting the movement of moisture is difficult but not impossible.
In this paper, failure analysis methodology will be applied to the principal mechanisms by which FBE coatings fail during long term service; with specific application to case studies involving blistering. The case studies apply standard failure analysis techniques to determine the primary causes and modes of failures.
We are unable to complete this action. Please try again at a later time.
If this error continues to occur, please contact AMPP Customer Support for assistance.
Use this error code for reference:
Please login to use Standards Credits*
* AMPP Members receive Standards Credits in order to redeem eligible Standards and Reports in the Store
You are not a Member.
AMPP Members enjoy many benefits, including Standards Credits which can be used to redeem eligible Standards and Reports in the Store.
You can visit the Membership Page to learn about the benefits of membership.
You have previously purchased this item.
Go to Downloadable Products in your AMPP Store profile to find this item.
You do not have sufficient Standards Credits to claim this item.
Click on 'ADD TO CART' to purchase this item.
Your Standards Credit(s)
1
Remaining Credits
0
Please review your transaction.
Click on 'REDEEM' to use your Standards Credits to claim this item.
You have successfully redeemed:
Go to Downloadable Products in your AMPP Store Profile to find and download this item.
Inspection has always been a hot topic when it comes to coatings projects. There are some substrates that can be harder to specify due to not knowing without knowing which testing is relevant to specify and properly inspect the substrate and surface after it is coated. Concrete is probably the number one substrate that is confusing. This paper will dive into the testing that is relevant when specifying coatings for concrete tanks and structures. Whether it is how to properly check film build or whether or not an ASTM test is relevant, this paper will clear the waters and make specifying coatings for concrete tanks and structures easier.
Industrial and marine protective coating systems are most commonly applied without incident and perform as expected over their anticipated service life. However, occasionally, a coating system will fail prematurely, for unexpected reasons, and with expensive consequences. This paper addresses those unexpected failures and provides reasons and remedies for such occurrences.