Long Term (20 Years) In-Service Performance of Concrete ICCP of Marine Wharf Structures in Australia

Impressed current cathodic protection (ICCP) is one corrosion management approach adopted by the Port of Newcastle (PoN) for their reinforced concrete wharves. The Port’s West Basin 3 wharf, has ICCP systems installed to select substructure concrete elements (beams). The West Basin 3 ICCP system to the front beam soffit section was installed in 1998 (rear beam soffit sections having been protected from 2014). Other ICCP systems have also been installed by the PoN during the period 2002 to 2005 for the West Basin Wharf 4, East Basin (1 & 2) wharves and the Kooragang K2 wharf. This paper provides background to the different ICCP systems utilized and details performance results for the West Basin 3 front beam ICCP system dating back more than 20 years. Monitoring results are presented and discussed. Performance assessment to protection criteria is undertaken and the CP system maintenance requirements are summarized. 

Product Number: 51320-14510-SG
Author: W. Green, S. Masia, N. Cambourn, J. Katen
Publication Date: 2020
$0.00
$20.00
$20.00
Also Purchased
Picture for 09072 Harsh Environment - ICCP System for Large Marine Loading Facility
Available for download

09072 Harsh Environment - ICCP System for Large Marine Loading Facility

Product Number: 51300-09072-SG
ISBN: 09072 2009 CP
Author: Richard Baxter and William Jamrok
Publication Date: 2009