Laboratory and field experiment results show that the soil resistivity is the main influencing factor of the cathodic protection current distribution of horizontal directional drilling. This article also gives a test method for effectiveness of cathodic protection of HDD.
The Horizontal Directional Drilling (HDD) process represents a significant improvement over traditional cut and cover methods for installing pipelines beneath obstructions. However, cathodic protection monitoring at HDD locations is typically limited to the entry/exit extremities, with protection levels in the intervening span either assumed or speculated. In this essay, the theoretical calculation method of current distribution on HDD will be shared. The laboratory and field experiment results show that the soil resistivity is the main influencing factor of the cathodic protection current distribution of the HDD. This article also gives a test method for the effectiveness of cathodic protection of HDD.
Key words: Horizontal directional drilling, Cathodic protection, Current and Potential Distribution
Case histories where throttling down the cathodic protection was evaluated to determine the impact on reducing the AC corrosion threat. Includes the use of fast-response electrical resistance corrosion rate probe monitoring technology.
We are unable to complete this action. Please try again at a later time.
If this error continues to occur, please contact AMPP Customer Support for assistance.
Error Message:
Please login to use Standards Credits*
* AMPP Members receive Standards Credits in order to redeem eligible Standards and Reports in the Store
You are not a Member.
AMPP Members enjoy many benefits, including Standards Credits which can be used to redeem eligible Standards and Reports in the Store.
You can visit the Membership Page to learn about the benefits of membership.
You have previously purchased this item.
Go to Downloadable Products in your AMPP Store profile to find this item.
You do not have sufficient Standards Credits to claim this item.
Click on 'ADD TO CART' to purchase this item.
Your Standards Credit(s)
1
Remaining Credits
0
Please review your transaction.
Click on 'REDEEM' to use your Standards Credits to claim this item.
You have successfully redeemed:
Go to Downloadable Products in your AMPP Store Profile to find and download this item.
This case history covers the stray current corrosion control program for a natural gas pipeline operator with assets influenced by operation of a nearby direct powered light rail transit system.