Search
Filters
Close

Save 20% on select titles with code HIDDEN24 - Shop The Sale Now

51318-11028-Some considerations on the use of coupon under stray direct traction current interference

Factors affecting the measurements of coupon polarization potential - in the presence of stray direct traction current - were investigated through field experiments. Based on results, suggestions were made for improving the use of coupons under those conditions.

 

Product Number: 51318-11028-SG
Author: Dezhi Tang / Yanxia Du / Jie liu / Minxu Lu / Shaosong Chen
Publication Date: 2018
$0.00
$20.00
$20.00

 

Coupons have been widely used for cathodic protection evaluation of buried metallic pipelines. Under stray direct traction current condition, however, the application of coupon techniques faces some challenges due to IR drop errors caused by the inherent stray current which cannot be interrupted. In this work, factors affecting the measurements of coupon polarization potential in the existence of stray direct traction current were investigated through field experiments. The results showed that the measured coupon polarization potential was significantly influenced by multiple parameters, such as polarization retention period, “instant-off” potential sampling delay, coupon burial depth, coupon-to-CSE interval, and the proximity of groundbeds. Based on the experimental results, practical suggestions were proposed for improving the proper use of coupons under dynamic stray direct current interference.

 

Key words: coupon, traction current interference, polarization retention, potential measurement

 

Coupons have been widely used for cathodic protection evaluation of buried metallic pipelines. Under stray direct traction current condition, however, the application of coupon techniques faces some challenges due to IR drop errors caused by the inherent stray current which cannot be interrupted. In this work, factors affecting the measurements of coupon polarization potential in the existence of stray direct traction current were investigated through field experiments. The results showed that the measured coupon polarization potential was significantly influenced by multiple parameters, such as polarization retention period, “instant-off” potential sampling delay, coupon burial depth, coupon-to-CSE interval, and the proximity of groundbeds. Based on the experimental results, practical suggestions were proposed for improving the proper use of coupons under dynamic stray direct current interference.

 

Key words: coupon, traction current interference, polarization retention, potential measurement

Also Purchased
Picture for 11338 Stray Current Interference from a Light Rail Traction System
Available for download

11338 Stray Current Interference from a Light Rail Traction System

Product Number: 51300-11338-SG
ISBN: 2011 11338 CP
Author: Earl L. Kirkpatrick
Publication Date: 2011
$20.00