Search
Filters
Close

Online Conference Paper

View as
Sort by
Display per page
Picture for A Mechanistic Study On The Effect Of Salt Concentration On Uniform Corrosion Rate Of Pipeline Steel In Acidic Aqueous Environments
Available for download

A Mechanistic Study On The Effect Of Salt Concentration On Uniform Corrosion Rate Of Pipeline Steel In Acidic Aqueous Environments

Product Number: 51321-16788-SG
Author: Fazlollah Madani Sani; Bruce Brown; Srdjan Nesic
Publication Date: 2021
$20.00
	Picture for A New Biocide Enhancer for a Better Pipeline Treatment
Available for download

A New Biocide Enhancer for a Better Pipeline Treatment

Product Number: 51324-20576-SG
Author: Nik Nor Azrizam Nik Norizam; Hasrizal A Rahman; Azmi Mohammed Nor
Publication Date: 2024
$40.00
Picture for A New Method to Mitigate Halite Deposit by Using Non-Water-Soluble Quaternary Ammonium Corrosion Inhibitor
Available for download

A New Method to Mitigate Halite Deposit by Using Non-Water-Soluble Quaternary Ammonium Corrosion Inhibitor

Product Number: 51324-20867-SG
Author: Dong Shen; Kung-Po Chao; Joseph E Penkala
Publication Date: 2024
$40.00
Picture for A New System of Corrosion Flow Loops and Some Experimental Results
Available for download

A New System of Corrosion Flow Loops and Some Experimental Results

Product Number: 51320-14435-SG
Author: Zhu Jin-yang, Jin Ying, Wen Lei, Xue Yan-peng, Honda Hiroshi
Publication Date: 2020
$20.00
Picture for A Novel Approach to Assessing Stray Current Interference without Potential Interruption
Available for download

A Novel Approach to Assessing Stray Current Interference without Potential Interruption

Product Number: 51324-20452-SG
Author: Parker B. Robbins
Publication Date: 2024
$40.00
A novel approach is proposed to assess a procedure for testing whether a pipeline may be interfered with from DC stray current. With the rise in popularity of portable coupons in AC mitigation testing, the paper proposes a method to evaluate DC stray current with a portable or stationary coupon without requiring potential interruption on foreign structures. This may allow technicians to conduct additional testing on suspected interference spots without requiring the interruption of a foreign pipeline or structure. This paper outlines and proposes a procedure for determining the likelihood of DC stray current interference utilizing coupons. Additionally, the paper recommends and outlines a proposed study to assess the accuracy of the techniques in the proposed procedure. While DC current cannot typically be measured and quantified for a bare metal holiday on a pipeline, coupons allow for a controlled and measurable connection to a simulated pipeline holiday. The procedure may be utilized to distinguish when suppressed potentials are occurring on a pipeline as a result of DC stray current interference rather than from inadequate current provided by CP system, a foreign voltage gradient, shielding or electrical grounding, even when the source of current is unknown. The procedure may also be beneficial in situations with atypical interring-structures where the existence of the interfering structure is unknown or where the applied voltage of the interfering structure cannot be interrupted traditionally such as with the prevalence of DC current situations occurring from installed or newly repaired direct-buried communication utility cables with weak splices at unknown locations. The procedure may also be utilized as an initial step to determine first steps in a DC stray current interference situation.
Picture for A Novel Corrosion Rate Monitoring Method For Steel In Soil Based On Tafel Extrapolation Method
Available for download

A Novel Corrosion Rate Monitoring Method For Steel In Soil Based On Tafel Extrapolation Method

Product Number: 51321-16967-SG
Author: Satoru Yamamoto; Masaru Abe; Kenkichi Tashiro
Publication Date: 2021
$20.00