51316-7127-Flow Accelerated Corrosion of Carbon Steel Pipe Carrying Hot Condensate Water in a Chemical Plant

Multiple leaks occurred with a carbon steel pipe carrying hot condensate water (300F and 140 psi).  A root cause analysis was performed, including visual and metallographic examination of two failed samples chemical, analysis of weld metal and base metal and chemical analysis of water samples.  Results show that flow accelerated corrosion (FAC) was the responsible mechanism leading to the failures.

Product Number: 51316-7127-SG
ISBN: 7127 2016 CP
Author: Fengmei Song
Publication Date: 2016
$0.00
$20.00
$20.00

Multiple leaks occurred with a carbon steel pipe carrying hot condensate water (300F and 140 psi). All leaks were shown localized and located in downstream of elbows immediately after the weld line. An extensive root cause analysis including visual and metallographic examination of two failed samples chemical analysis of weld metal and base metal and chemical analysis of water samples was performed and results clearly show that flow accelerated corrosion (FAC) was the responsible mechanism leading to the failures. Other mechanisms including organic acid corrosion and erosion corrosion were ruled out based on sampled water pH being alkaline and water flow velocity relatively low. The pipe was replaced by 316 stainless steel pipe to prevent FAC. 316 stainless steel is also immune to organic acid corrosion if it ever becomes a threat.

Keywords: downloadable, flow accelerated corrosion, weld, carbon steel, erosion-corrosion, chemical plant

Multiple leaks occurred with a carbon steel pipe carrying hot condensate water (300F and 140 psi). All leaks were shown localized and located in downstream of elbows immediately after the weld line. An extensive root cause analysis including visual and metallographic examination of two failed samples chemical analysis of weld metal and base metal and chemical analysis of water samples was performed and results clearly show that flow accelerated corrosion (FAC) was the responsible mechanism leading to the failures. Other mechanisms including organic acid corrosion and erosion corrosion were ruled out based on sampled water pH being alkaline and water flow velocity relatively low. The pipe was replaced by 316 stainless steel pipe to prevent FAC. 316 stainless steel is also immune to organic acid corrosion if it ever becomes a threat.

Keywords: downloadable, flow accelerated corrosion, weld, carbon steel, erosion-corrosion, chemical plant

Also Purchased
Picture for 99347 FLOW-ACCELERATED CORROSION
Available for download

99347 FLOW-ACCELERATED CORROSION

Product Number: 51300-99347-SG
ISBN: 99347 1999 CP
Author: R.B. Dooley and V.K. Chexal
$20.00
Picture for Flow Accelerated Corrosion—Causes Detection and Mitigation
Available for download

51315-5574-Flow Accelerated Corrosion—Causes, Detection, and Mitigation

Product Number: 51315-5574-SG
ISBN: 5574 2015 CP
Author: Aaron Kelley
Publication Date: 2015
$20.00
Picture for 98721 FLOW ACCELERATED CORROSION
Available for download

98721 FLOW ACCELERATED CORROSION

Product Number: 51300-98721-SG
ISBN: 98721 1998 CP
Author: R D. Port
$20.00