Cross-Linking Performance to Mechanism: Correlation of lining performance in flue gas desulfurization applications to cure mechanism

Some of the toughest environments for protective coatings to withstand are seen in the power industry, particularly within the flue gas desulfurization (FGD) process. Temperatures within the different areas throughout the system may reach 350-450°F (177-232°C) and then be cooled to ambient temperatures upon shutdown of the unit. 

Product Number: 41212-703-SG
Author: Andrew Recker
Publication Date: 2012
$0.00
$20.00
$20.00

Some of the toughest environments for protective coatings to withstand are seen in the power industry, particularly within the flue gas desulfurization (FGD) process. Temperatures within the different areas throughout the system may reach 350-450°F (177-232°C) and then be cooled to ambient temperatures upon shutdown of the unit. The cooling causes oxidized sulphur to condense with the moisture forming sulphuric acid. This heating and cooling put tremendous stress on the lining as it shrinks and expands combined with post cure stresses. The lining also undergoes attack by sulphuric acid which can react with the lining, basically dissolving it from the substrate. In this environment, a lining’s cross-link density is critical to the survival in this harsh environment.

Some of the toughest environments for protective coatings to withstand are seen in the power industry, particularly within the flue gas desulfurization (FGD) process. Temperatures within the different areas throughout the system may reach 350-450°F (177-232°C) and then be cooled to ambient temperatures upon shutdown of the unit. The cooling causes oxidized sulphur to condense with the moisture forming sulphuric acid. This heating and cooling put tremendous stress on the lining as it shrinks and expands combined with post cure stresses. The lining also undergoes attack by sulphuric acid which can react with the lining, basically dissolving it from the substrate. In this environment, a lining’s cross-link density is critical to the survival in this harsh environment.

Product tags
Also Purchased
Picture for 08519 A History of Coatings and Linings as Corrosion Protection in Flue Gas Desulfurization Plants
Available for download

08519 A History of Coatings and Linings as Corrosion Protection in Flue Gas Desulfurization Plants

Product Number: 51300-08519-SG
ISBN: 08519 2008 CP
Author: Jurgen Fenner, Wolfgang Berger, and Patrick Pfeil
Publication Date: 2008
$20.00
Picture for 96398 COST EFFECTIVE MATERIALS FOR FLUE
Available for download

96398 COST EFFECTIVE MATERIALS FOR FLUE GAS DESULFURIZATION (FGD)

Product Number: 51300-96398-SG
ISBN: 96398 1996 CP
Author: Don H. Kelley, Bob Brady
$20.00
Picture for 06559 Re-Lining of a Flue Gas Desulfurization
Available for download

06559 Re-Lining of a Flue Gas Desulfurization Plant Scrubber

Product Number: 51300-06559-SG
ISBN: 06559 2006 CP
Author: W. Berger, J. Fenner