The primary structure of many outdoor baseball parks and football stadiums is exposed structural steel. These facilities are often located in major cities in areas that may present challenges in control of corrosion. The challenge is also manifested in the fact that the structural steel frame becomes an architectural feature which must be maintained as an aesthetic element.
The primary structure of many outdoor baseball parks and football stadiums is exposed structural steel. These facilities are often located in major cities in areas that may present challenges in control of corrosion. The challenge is also manifested in the fact that the structural steel frame becomes an architectural feature which must be maintained as an aesthetic element. The high-profile nature of these facilities obligates the facility owners to maintain a clean and bright environment for the thousands of fans and urban visitors that view the facilities. Unsightly connections and spot rusting are seen as lack of maintenance and can reflect badly on the image of a team.
A brief history of cycles of exterior intumescent coating repair is presented; types of coating failure are identified; various depths of repair are illustrated; discoveries regarding the initial coating and; difficulties in effecting repairs are discussed.
We are unable to complete this action. Please try again at a later time.
If this error continues to occur, please contact AMPP Customer Support for assistance.
Use this error code for reference:
Please login to use Standards Credits*
* AMPP Members receive Standards Credits in order to redeem eligible Standards and Reports in the Store
You are not a Member.
AMPP Members enjoy many benefits, including Standards Credits which can be used to redeem eligible Standards and Reports in the Store.
You can visit the Membership Page to learn about the benefits of membership.
You have previously purchased this item.
Go to Downloadable Products in your AMPP Store profile to find this item.
You do not have sufficient Standards Credits to claim this item.
Click on 'ADD TO CART' to purchase this item.
Your Standards Credit(s)
1
Remaining Credits
0
Please review your transaction.
Click on 'REDEEM' to use your Standards Credits to claim this item.
You have successfully redeemed:
Go to Downloadable Products in your AMPP Store Profile to find and download this item.
Cracks in a concrete substrate pose a challenge for coatings. Cracks that are not properly identified and addressed can lead to premature failure of the coating. This paper will discuss the forces that cause cracking in concrete structures, as well as crack types and repair techniques.
In this paper the approach of an Oil Company is demonstrated from the initial choice between different primers: inorganic zinc and organic (epoxy) zinc., to all the preliminary pre-qualification tests, the subsequently field test performed, and the procedures adopted, costs included.