Search
Filters
Close

98529 COOLING TOWER FILL FOULING CONTROL IN A GEOTHERMAL POWER PLANT

Product Number: 51300-98529-SG
ISBN: 98529 1998 CP
Author: F. Philip Yu, L. Dewayne Ginn, William F. McCoy, Henry Castanieto
$0.00
$20.00
$20.00
Since its first introduction to the market in the 1970s, cooling tower film fill technology has significantly increased thermal performance and reduced the size of cooling towers. However, the narrow spaces between film fill sheets make them susceptible to fouling. Without proper chemical treatment, deposits can accumulate within the film fill resulting in reduced tower efficiency, increased fouling and plugging of the fill. These phenomena could eventually lead to collapse of the tower structure. This paper describes a new approach to remedy the high efficiency film fill fouling problem in a geothermal power plant. The plant has a long history of fill fouling problems due to a very complex make-up water chemistry and desert-related environmental conditions. In recent years, various biocide and biodispersant treatments have significantly improved fouling control by slowing down tower fill deposition rates. However, no program has been successful in reducing fill weights, especially during the summer months. Within six weeks after starting a new control program, the average weight of the tower fill deposits dropped 22% and thermal performance of the cooling tower increased 20%. The treatment resulted in significant improvements in cooling tower operation and power production efficiency. Keywords: film fill, cooling tower, biofouling, biocide, biodispersant, thermal efficiency
Since its first introduction to the market in the 1970s, cooling tower film fill technology has significantly increased thermal performance and reduced the size of cooling towers. However, the narrow spaces between film fill sheets make them susceptible to fouling. Without proper chemical treatment, deposits can accumulate within the film fill resulting in reduced tower efficiency, increased fouling and plugging of the fill. These phenomena could eventually lead to collapse of the tower structure. This paper describes a new approach to remedy the high efficiency film fill fouling problem in a geothermal power plant. The plant has a long history of fill fouling problems due to a very complex make-up water chemistry and desert-related environmental conditions. In recent years, various biocide and biodispersant treatments have significantly improved fouling control by slowing down tower fill deposition rates. However, no program has been successful in reducing fill weights, especially during the summer months. Within six weeks after starting a new control program, the average weight of the tower fill deposits dropped 22% and thermal performance of the cooling tower increased 20%. The treatment resulted in significant improvements in cooling tower operation and power production efficiency. Keywords: film fill, cooling tower, biofouling, biocide, biodispersant, thermal efficiency
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 98527 ASPECTS OF COOLING TOWER BIOCIDES
Available for download

98527 ASPECTS OF COOLING TOWER BIOCIDES AND PROTOZOA

Product Number: 51300-98527-SG
ISBN: 98527 1998 CP
Author: S.G. Berk, R.J. Ashburn, R.S. Ting
$20.00
Picture for 00438 DEVELOPMENT OF PRETREATMENTS FOR
Available for download

00438 DEVELOPMENT OF PRETREATMENTS FOR COOLING WATER SYSTEMS

Product Number: 51300-00438-SG
ISBN: 00438 2000 CP
Author: Mark A. Moore, Abdullah I. Mahrous, Paul Frazer and Sulaiman A1-Jutaily
$20.00
Picture for 02402 ADVANCED SCALE CONTROL...
Available for download

02402 ADVANCED SCALE CONTROL TECHNOLOGY FOR COOLING WATER SYSTEMS

Product Number: 51300-02402-SG
ISBN: 02402 2002 CP
Author: Stephen M. Kessler
$20.00