Search
Filters
Close

Celebrate World Corrosion Awareness Day with 20% off eCourses and eBooks with code WCAD2024 at checkout!

98077 INTERNAL CORROSION MONITORING OF SUBSEA PRODUCTION FLOWLINES - PROBE DESIGN AND TESTING

Product Number: 51300-98077-SG
ISBN: 98077 1998 CP
Author: M. W. Joosten, J. Kolts, P. G. Humble, T. J. Blakset, D. M. Keilty
$0.00
$20.00
$20.00
This paper addresses one technique for acquiring subsea corrosion rate data. Subsea monitoring provides the advantage of measuring the corrosion inhibitor efficacy at the point of injection, rather than inferring performance from platform measurements. The internal condition of pipelines can be monitored in a variety of ways. The optimum monitoring technique will change with pipeline age, location, accessibility, and operating conditions. More importantly, the applicable methods may change based on the type of information required. For evaluation of corrosion inhibitor performance a high-sensitivity corrosion monitor is required. A prototype dual-element, electric-resistance probe has been evaluated for pressure and temperature stability under simulated Britannia subsea operating conditions. The probe functioned well under all conditions over an extensive test period. As expected, temperature had the greatest impact on the stability of the corrosion measurements. Interpretation of the relative response of the dual probes to the variety of test conditions is useful in evaluating the validity of field data and the tinctionality of the probe. Issues, revealed by the testing program, included anomalous data points and fluid behind the probe elements. The anomalous data were easily identifiable, but disrupted the automated calculation of the corrosion rate. A loose connection caused the anomalous data points. Ingress of fluid behind the probe element is still a concern for long term exposures. Keywords: Corrosion Monitoring, Subsea, Electric Resistance Probe, ER Probe, Design, Construction, Testing
This paper addresses one technique for acquiring subsea corrosion rate data. Subsea monitoring provides the advantage of measuring the corrosion inhibitor efficacy at the point of injection, rather than inferring performance from platform measurements. The internal condition of pipelines can be monitored in a variety of ways. The optimum monitoring technique will change with pipeline age, location, accessibility, and operating conditions. More importantly, the applicable methods may change based on the type of information required. For evaluation of corrosion inhibitor performance a high-sensitivity corrosion monitor is required. A prototype dual-element, electric-resistance probe has been evaluated for pressure and temperature stability under simulated Britannia subsea operating conditions. The probe functioned well under all conditions over an extensive test period. As expected, temperature had the greatest impact on the stability of the corrosion measurements. Interpretation of the relative response of the dual probes to the variety of test conditions is useful in evaluating the validity of field data and the tinctionality of the probe. Issues, revealed by the testing program, included anomalous data points and fluid behind the probe elements. The anomalous data were easily identifiable, but disrupted the automated calculation of the corrosion rate. A loose connection caused the anomalous data points. Ingress of fluid behind the probe element is still a concern for long term exposures. Keywords: Corrosion Monitoring, Subsea, Electric Resistance Probe, ER Probe, Design, Construction, Testing
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 98078 FIELD TRAILS FOR CORROSION INHIBITOR
Available for download

98078 FIELD TRAILS FOR CORROSION INHIBITOR SELECTION AND OPTIMISATION, USING A NEW GENERATION OF ELECTRICAL RESISTANCE PROBES

Product Number: 51300-98078-SG
ISBN: 98078 1998 CP
Author: B. RIDD, T.J. BLAKSET, D. QUEEN
$20.00
Picture for Portable Online 4-Probe Sensor for Simultaneous Monitoring of Corrosion Rate and SRB Activity
Available for download

51313-02148-Portable Online 4-Probe Sensor for Simultaneous Monitoring of Corrosion Rate and SRB Activity

Product Number: 51313-02148-SG
ISBN: 02148 2013 CP
Author: Sankara Papavinasam
Publication Date: 2013
$20.00
Picture for 02105 NEW PROBE FOR CP POTENTIAL...
Available for download

02105 NEW PROBE FOR CP POTENTIAL MONITORING IN SOIL

Product Number: 51300-02105-SG
ISBN: 02105 2002 CP
Author: Luciano Lazzari, Marco Ormellese, and MariaPia Pedeferri
$20.00