96321 PENETRATION OF CHLORIDES AND REBAR CORROSION IN CONCRETE COLUMNS OF TWO BUILDINGS AT A MARINE SITE

Product Number: 51300-96321-SG
ISBN: 96321 1996 CP
Author: P. Castro, R. Castillo, L. Maldonado
$0.00
$20.00
$20.00
A corrosion potential mapping and a chloride content survey were done in two public buildings in the port of Progreso, Yucatan, Mexico, in order to detect the chloride penetration mechanisms that could be related to the observed corrosion processes. The Center for Marine Technical Studies (CETMAR) and High School # 6 (ES6) are schools constructed at the seashore and at 800 m. from the shoreline, respectively. The preliminary inspection evaluated the direction in which the aggressive agents are acting, the topography of the land and the damaged zones. A detailed inspection of the schools showed that chloride penetration from the soil and roof to the middle of the columns is the mechanism related to the observed corrosion deterioration, A relation between corrosion potentials and the levels of chloride concentrations in the rcbar vicinity was also observed with some limitations that are discussed. The results indicated that, in front of the sea, the chlorides that penetrate the concrete axially from the foundation, are more related to the observed corrosion process than those that penetrate it from the surface. At 800 m. from the shoreline it happens the other way. Keywords: chlorides, chloride penetration, infrastructure, rebars, concrete columns, preliminary inspection. detailed inspection, potential mapping
A corrosion potential mapping and a chloride content survey were done in two public buildings in the port of Progreso, Yucatan, Mexico, in order to detect the chloride penetration mechanisms that could be related to the observed corrosion processes. The Center for Marine Technical Studies (CETMAR) and High School # 6 (ES6) are schools constructed at the seashore and at 800 m. from the shoreline, respectively. The preliminary inspection evaluated the direction in which the aggressive agents are acting, the topography of the land and the damaged zones. A detailed inspection of the schools showed that chloride penetration from the soil and roof to the middle of the columns is the mechanism related to the observed corrosion deterioration, A relation between corrosion potentials and the levels of chloride concentrations in the rcbar vicinity was also observed with some limitations that are discussed. The results indicated that, in front of the sea, the chlorides that penetrate the concrete axially from the foundation, are more related to the observed corrosion process than those that penetrate it from the surface. At 800 m. from the shoreline it happens the other way. Keywords: chlorides, chloride penetration, infrastructure, rebars, concrete columns, preliminary inspection. detailed inspection, potential mapping
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 96324 STUDY OF CORROSION BEHAVIOUR OF HIGH
Available for download

96324 STUDY OF CORROSION BEHAVIOUR OF HIGH STRENGTH LOW ALLOY STEEL REINFORCING BARS IN INDUSTRIAL AND MARINE ENVIRONMENTS

Product Number: 51300-96324-SG
ISBN: 96324 1996 CP
Author: S. K. Singh, M. G. Hocking, R.Jha, Amit Chatterjee, T.Mukherjee
$20.00
Picture for 96320 PILINGS OF THE GENERAL RAFAEL
Available for download

96320 PILINGS OF THE GENERAL RAFAEL URDANETA BRIDGE: ELECTROCHEMICAL DIAGNOSIS AND REHABILITATION

Product Number: 51300-96320-SG
ISBN: 96320 1996 CP
Author: Oladis T. de Rincon, Matilde F. de Romero, Daniel Contreras, Oleyda Moron, Jesus Ludovic, Jose Bravo
$20.00
Picture for 96312 FIELD APPLICATION OF CATHODIC PREVENTION
Available for download

96312 FIELD APPLICATION OF CATHODIC PREVENTION ON REINFORCED CONCRETE STRUCTURES

Product Number: 51300-96312-SG
ISBN: 96312 1996 CP
Author: Alberto Bazzoni, Bruno Bazzoni, Luciano Lazzari, Luca Bertolini, Pietro Pedeferri
$20.00