Search
Filters
Close

96324 STUDY OF CORROSION BEHAVIOUR OF HIGH STRENGTH LOW ALLOY STEEL REINFORCING BARS IN INDUSTRIAL AND MARINE ENVIRONMENTS

Product Number: 51300-96324-SG
ISBN: 96324 1996 CP
Author: S. K. Singh, M. G. Hocking, R.Jha, Amit Chatterjee, T.Mukherjee
Industry: Highways & Bridges
$0.00
$20.00
$20.00
Mild steel reinforcing bars embedded in concrete exposed 10 marine environmcnt are prone to severe corrosion lending to serious damage to the structures. The various technologies developed and adopted to reduce the corrosion of steel reinforcement have been discussed in this paper along with a new high strength alloy (HSLA) steel reinforcing bar. The bare HSLA rebars heve been tested extensively along with mild steel rebars for comparative study in saline and sulphurous electrolytes in the laboratory by Potentiodynamic testsas well as in natural marine and industrial environments. The HSLA and mild steel rebars embedded in concrete were also tcsled in saline water by alternate immersion test and by impressed anodic current methods. Tbe bare HSLA rebars showed 2-3 and 1.5- 1.9 times better corrosion resistance to mild steel rebars in laboratory and field exposure tests respectively. The HSLA rebars embedded in concrete and exposed to saline water with impressed anodic current of 200... Keywords: rebar, HSLA Steel, concrete, marine environment, corrosion resistance, potentiodynamic test, field exposure, impressed current.
Mild steel reinforcing bars embedded in concrete exposed 10 marine environmcnt are prone to severe corrosion lending to serious damage to the structures. The various technologies developed and adopted to reduce the corrosion of steel reinforcement have been discussed in this paper along with a new high strength alloy (HSLA) steel reinforcing bar. The bare HSLA rebars heve been tested extensively along with mild steel rebars for comparative study in saline and sulphurous electrolytes in the laboratory by Potentiodynamic testsas well as in natural marine and industrial environments. The HSLA and mild steel rebars embedded in concrete were also tcsled in saline water by alternate immersion test and by impressed anodic current methods. Tbe bare HSLA rebars showed 2-3 and 1.5- 1.9 times better corrosion resistance to mild steel rebars in laboratory and field exposure tests respectively. The HSLA rebars embedded in concrete and exposed to saline water with impressed anodic current of 200... Keywords: rebar, HSLA Steel, concrete, marine environment, corrosion resistance, potentiodynamic test, field exposure, impressed current.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 96310 REMOTE MONITORING SYSTEMS FOR THE
Available for download

96310 REMOTE MONITORING SYSTEMS FOR THE CATHODIC PROTECTION OF REINFORCED CONCRETE

Product Number: 51300-96310-SG
ISBN: 96310 1996 CP
Author: Gerard Benchetrit
$20.00
Picture for 96312 FIELD APPLICATION OF CATHODIC PREVENTION
Available for download

96312 FIELD APPLICATION OF CATHODIC PREVENTION ON REINFORCED CONCRETE STRUCTURES

Product Number: 51300-96312-SG
ISBN: 96312 1996 CP
Author: Alberto Bazzoni, Bruno Bazzoni, Luciano Lazzari, Luca Bertolini, Pietro Pedeferri
$20.00
Picture for 96323 IMPROVING THE PERFORMANCE OF FUSION-
Available for download

96323 IMPROVING THE PERFORMANCE OF FUSION-BONDED EPOXY COATED STEEL REINFORCING BARS

Product Number: 51300-96323-SG
ISBN: 96323 1996 CP
Author: Robert D. Lampton, Jr., Dieter Schemberger
$20.00