Search
Filters
Close

96192 PROTECTING TWO HIGH PRESSURE NATURAL GAS LINES IN A WETLAND AREA

Product Number: 51300-96192-SG
ISBN: 96192 1996 CP
Author: John H. Fitzgerald III, Joseph Skubisz, Frank Schaefer
$0.00
$20.00
$20.00
Among the various high pressure pipelines operated by a natural gas company in Chicago, Illinois are two parallel 24-inch lines that traverse about a mile (1.6 km) of wetland. In 1995 it became necessary to rehabilitate the cathodic protection on these pipelines It was necessary to design and install an impressed current system that would meet the environmental requirement of preserving the wetland while at the same time providing adequate protection to the pipelines. This was accomplished by using a long horizontal groundbed consisting of anodes and cokebreeze within a porous cloth bag. This was pulled through a directionally drilled hole beneath the surface of the wetland and connected to an existing rectifier that had been installed some years ago. The entire operation took place with no damage to the wetland and the owner was able to meet its environmental responsibility as well as its responsibility under the DOT regulations. Keywords: cathodic protection, gas pipelines, environmental issues, wetland.
Among the various high pressure pipelines operated by a natural gas company in Chicago, Illinois are two parallel 24-inch lines that traverse about a mile (1.6 km) of wetland. In 1995 it became necessary to rehabilitate the cathodic protection on these pipelines It was necessary to design and install an impressed current system that would meet the environmental requirement of preserving the wetland while at the same time providing adequate protection to the pipelines. This was accomplished by using a long horizontal groundbed consisting of anodes and cokebreeze within a porous cloth bag. This was pulled through a directionally drilled hole beneath the surface of the wetland and connected to an existing rectifier that had been installed some years ago. The entire operation took place with no damage to the wetland and the owner was able to meet its environmental responsibility as well as its responsibility under the DOT regulations. Keywords: cathodic protection, gas pipelines, environmental issues, wetland.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 96198 Case Histories of External Microbiologically
Available for download

96198 Case Histories of External Microbiologically Influenced Corrosion Underneath Disbonded Coatings

Product Number: 51300-96198-SG
ISBN: 96198 1996 CP
Author: Joseph L. Pikas
$20.00
Picture for 96199 Shear Strength Testing of Pipeline Coatings
Available for download

96199 Shear Strength Testing of Pipeline Coatings and Soil Stress

Product Number: 51300-96199-SG
ISBN: 96199 1996 CP
Author: Jordan D. Kellner
$20.00
Picture for 96193 CATHODIC PROTECTION OF PRODUCT
Available for download

96193 CATHODIC PROTECTION OF PRODUCT PIPELINES IN A REFINERY USING DEEP ANODE GROUNDBEDS IN AN AREA OF CONCERN FOR CROSS CONTAMINATION OF MULTIPLE AQUIFERS

Product Number: 51300-96193-SG
ISBN: 96193 1996 CP
Author: John H. Fitzgerald III, David Hutton
$20.00