11012 Multi-Zone Cathodic Protection Monitoring for Bridge Applications

Product Number: 51300-11012-SG
ISBN: 2011 11012 CP
Author: Jamey Hilleary
Publication Date: 2011
$0.00
$20.00
$20.00

The highway bridge infrastructure includes a number of structures in need of replacement or significant rehabilitation work. The respective state’s departments of transportation bear the primary responsibility for the integrity and safety of the nation’s bridges. These departmental budgets are under significant strain nationwide and this is affecting the challenges involving corrosion prevention on these structures in several ways: Bridge rehabilitation for life extension often involves the introduction of impressed current cathodic protection systems for encased rebar. Limited budgets reduce the number of trained personnel to operate and maintain the systems. The personnel used often have minimal training in the area of cathodic protection. The data forwarded to the CP engineer can be incomplete and there are numerous opportunities for interjection of human error. The field sites from which the data is acquired are often in very dangerous highway locations, making data acquisition both difficult and hazardous. Developing a cost effective way to accurately acquire all of this data in an organized manner and on a timely schedule provided a unique challenge. Standard GSM remote monitoring equipment was designed into a 5-zone (15 channel), “Bridge Zone Monitor System” allowing each zone to be accessed as a discreet site while sharing the communication system with the other zones at the site.

Key words: cathodic protection, multi-zone rectifiers, bridge rehabilitation, remote monitoring.

The highway bridge infrastructure includes a number of structures in need of replacement or significant rehabilitation work. The respective state’s departments of transportation bear the primary responsibility for the integrity and safety of the nation’s bridges. These departmental budgets are under significant strain nationwide and this is affecting the challenges involving corrosion prevention on these structures in several ways: Bridge rehabilitation for life extension often involves the introduction of impressed current cathodic protection systems for encased rebar. Limited budgets reduce the number of trained personnel to operate and maintain the systems. The personnel used often have minimal training in the area of cathodic protection. The data forwarded to the CP engineer can be incomplete and there are numerous opportunities for interjection of human error. The field sites from which the data is acquired are often in very dangerous highway locations, making data acquisition both difficult and hazardous. Developing a cost effective way to accurately acquire all of this data in an organized manner and on a timely schedule provided a unique challenge. Standard GSM remote monitoring equipment was designed into a 5-zone (15 channel), “Bridge Zone Monitor System” allowing each zone to be accessed as a discreet site while sharing the communication system with the other zones at the site.

Key words: cathodic protection, multi-zone rectifiers, bridge rehabilitation, remote monitoring.

Product tags
Also Purchased
Picture for 00728 COMPUTERIZED CATHODIC PROTECTION OPERATION
Available for download

00728 COMPUTERIZED CATHODIC PROTECTION OPERATION AND MONITORING BURIED PIPELINES

Product Number: 51300-00728-SG
ISBN: 00728 2000 CP
Author: Helge Hafnor and Birger Amundsen
$20.00
Picture for 09456 Intelligent Remote Monitoring System for Cathodic Protection of Transmission Pipelines
Available for download

09456 Intelligent Remote Monitoring System for Cathodic Protection of Transmission Pipelines

Product Number: 51300-09456-SG
ISBN: 09456 2009 CP
Author: Gervasio F. Pimenta, Andres B. Peratta, John M W Baynham and Robert A. Adey
Publication Date: 2009
$20.00
Picture for 10127 Rehabilitation of  Historical Bridge Exhibiting Severe Corrosion Damage in Florida
Available for download

10127 Rehabilitation of Historical Bridge Exhibiting Severe Corrosion Damage in Florida

Product Number: 51300-10127-SG
ISBN: 10127 2010 CP
Author: Richard J. Kessler, Ivan R. Lasa, Mario A. Paredes
Publication Date: 2010
$20.00