09436 Vapor Space Stress Corrosion Cracking of Radioactive High Level Waste Tanks

Product Number: 51300-09436-SG
ISBN: 09436 2009 CP
Author: Karthik Subramanian, Philip E. Zapp and Bruce J. Wiersma
Publication Date: 2009
$0.00
$20.00
$20.00
Radioactive waste primarily containing sodium nitrate, nitrite, and hydroxide is stored in underground storage tanks at the Department of Energy (DOE) Savannah River Site (SRS). A comprehensive structural integrity program, which includes chemistry controls, is in place to preclude any consequential corrosion in these waste tanks to maintain safe storage of the waste. Sodium hydroxide and nitrite are used to inhibit nitrate-induced stress corrosion cracking and nitrate-induced pitting corrosion in the liquid phase of the waste tanks. Although these solution chemistry controls are in place, recent experience has shown that steel not in contact with the bulk waste solution or slurry, but exposed to the “vapor space” above the bulk waste, may be vulnerable to the initiation and propagation of corrosion, including pitting and stress corrosion cracking.

Recent laboratory testing has not been successful in recreating vapor space cracking seen in the waste tanks. Subsequent testing is planned to better simulate tank conditions.

Keywords: carbon steel, nitrate, pitting
Radioactive waste primarily containing sodium nitrate, nitrite, and hydroxide is stored in underground storage tanks at the Department of Energy (DOE) Savannah River Site (SRS). A comprehensive structural integrity program, which includes chemistry controls, is in place to preclude any consequential corrosion in these waste tanks to maintain safe storage of the waste. Sodium hydroxide and nitrite are used to inhibit nitrate-induced stress corrosion cracking and nitrate-induced pitting corrosion in the liquid phase of the waste tanks. Although these solution chemistry controls are in place, recent experience has shown that steel not in contact with the bulk waste solution or slurry, but exposed to the “vapor space” above the bulk waste, may be vulnerable to the initiation and propagation of corrosion, including pitting and stress corrosion cracking.

Recent laboratory testing has not been successful in recreating vapor space cracking seen in the waste tanks. Subsequent testing is planned to better simulate tank conditions.

Keywords: carbon steel, nitrate, pitting
Product tags
Also Purchased
Picture for 08595 Current Corrosion Issues in DOE Radioactive High Level Waste Tanks
Available for download

08595 Current Corrosion Issues in DOE Radioactive High Level Waste Tanks

Product Number: 51300-08595-SG
ISBN: 08595 2008 CP
Author: K. Subramanian, B. Wiersma, and P. Zapp
Publication Date: 2008
$20.00
Picture for 09327 Corrosion Resistance of Various Glass Fiber Reinforcements
Available for download

09327 Corrosion Resistance of Various Glass Fiber Reinforcements

Product Number: 51300-09327-SG
ISBN: 09327 2009 CP
Author: Kevin Spoo
Publication Date: 2009
$20.00
Picture for 09432 Localized Corrosion of A537 Steel in Simulated Waste Tank Solution
Available for download

09432 Localized Corrosion of A537 Steel in Simulated Waste Tank Solution

Product Number: 51300-09432-SG
ISBN: 09432 2009 CP
Author: Philip E. Zapp, Elizabeth Hoffman, Karthik Subramanian and B. J. Wiersma
Publication Date: 2009
$20.00