Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

08107 Sulfide Fracture Toughness of Low-alloy Steel OCTG in Mild Conditions at Room Temperature and at 40 F

Product Number: 51300-08107-SG
ISBN: 08107 2008 CP
Author: David L. Sponseller, Thomas E. Sponseller, and Bruce E. Urband
Publication Date: 2008
$0.00
$20.00
$20.00
This study was initiated under API sponsorship to explore the use of very high strength OCTG in formations having lower H2S concentrations and/or higher pH and colder temperatures. Samples from four commercial pipes, each supplied by a different producer and spanning a wide range of hardness values and yield strengths, were examined by the double-cantilever-beam (DCB) test for their resistance to sulfide stress cracking in mild environments at room and low temperatures. Testing parameters were developed to accommodate the very wide range of cracking tendencies resulting from the markedly different mechanical properties and chemical conditions, ranging from standard to 1% H2S / 4.5 pH, at both room temperature and 40° F. At the mildest condition average values of sulfide fracture toughness as high as 70.1 and 64.1 ksi-vin. (77.0 and 70.4 MPa-vm) were achieved at room temperature and 40° F, respectively. Extrapolations to high strength levels suggest the possibility of using C-125 tubulars in the mildest conditions.
This study was initiated under API sponsorship to explore the use of very high strength OCTG in formations having lower H2S concentrations and/or higher pH and colder temperatures. Samples from four commercial pipes, each supplied by a different producer and spanning a wide range of hardness values and yield strengths, were examined by the double-cantilever-beam (DCB) test for their resistance to sulfide stress cracking in mild environments at room and low temperatures. Testing parameters were developed to accommodate the very wide range of cracking tendencies resulting from the markedly different mechanical properties and chemical conditions, ranging from standard to 1% H2S / 4.5 pH, at both room temperature and 40° F. At the mildest condition average values of sulfide fracture toughness as high as 70.1 and 64.1 ksi-vin. (77.0 and 70.4 MPa-vm) were achieved at room temperature and 40° F, respectively. Extrapolations to high strength levels suggest the possibility of using C-125 tubulars in the mildest conditions.
Product tags
Also Purchased
Picture for 08108 Interpreting and Using the NACE Double Cantilever Beam (DCB) Test
Available for download

08108 Interpreting and Using the NACE Double Cantilever Beam (DCB) Test

Product Number: 51300-08108-SG
ISBN: 08108 2008 CP
Author: Karol E. Szklarz
Publication Date: 2008
$20.00
Picture for 08115 Development of a C125 High Strength Low Alloy Steel for OCTG: SSC Mapping in Slightly Sour Environment
Available for download

08115 Development of a C125 High Strength Low Alloy Steel for OCTG: SSC Mapping in Slightly Sour Environment

Product Number: 51300-08115-SG
ISBN: 08115 2008 CP
Author: Hervé Marchebois / Michel Piette / Laurent Ladeuille / David Senegas-Rouviere /Christoph Bosch / Josef Pleschiutschnig / Jean Leyer / Bertine Orlans-Joliet / Etienne Lepine / Frédéric Legay / Cédric Linne / Alfredo Figueiredo
Publication Date: 2008
$20.00