Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

08098 Downhole CRA Materials Performance - Failure Analysis of a Sub Surface Safety Valve

Product Number: 51300-08098-SG
ISBN: 08098 2008 CP
Author: Jonathan Marsh
Publication Date: 2008
$0.00
$20.00
$20.00
This publication discusses the failure of a sub surface safety valve (SSSV) from a sour service gas well in the Mobile Bay area of Alabama, after four years in service. The well in question was prone to sulphide scale formation from metal sulphides in the formation water. The history of the SSSV began as a work over of an existing well, where installation occurred. Also installed simultaneously with the SSSV and the tubing string were two chemical injection points (lower and upper) for scale inhibitor injection. The lower injection point failed immediately, leading to the use of frequent acidizing treatments (acid jobs) to provide flow assurance in the well tubing. The upper injection point failed after 2 years in service. This lead to some malfunctioning of the SSSV due to scaling, and an increased frequency of acidizing to ensure SSSV functionality. However, after a further year of operation the SSSV stuck in the open position and could no longer be freed by acidizing alone. Mechanical manipulation via slick line and an exercise tool restored functionality to the SSSV, which could then be operated by control line pressure. After this point functionality of the SSSV could only be maintained by mechanical manipulation in addition to acidizing.
This publication discusses the failure of a sub surface safety valve (SSSV) from a sour service gas well in the Mobile Bay area of Alabama, after four years in service. The well in question was prone to sulphide scale formation from metal sulphides in the formation water. The history of the SSSV began as a work over of an existing well, where installation occurred. Also installed simultaneously with the SSSV and the tubing string were two chemical injection points (lower and upper) for scale inhibitor injection. The lower injection point failed immediately, leading to the use of frequent acidizing treatments (acid jobs) to provide flow assurance in the well tubing. The upper injection point failed after 2 years in service. This lead to some malfunctioning of the SSSV due to scaling, and an increased frequency of acidizing to ensure SSSV functionality. However, after a further year of operation the SSSV stuck in the open position and could no longer be freed by acidizing alone. Mechanical manipulation via slick line and an exercise tool restored functionality to the SSSV, which could then be operated by control line pressure. After this point functionality of the SSSV could only be maintained by mechanical manipulation in addition to acidizing.
Product tags
Also Purchased
Picture for 04115 Failure Analysis of a Leaking Slab Valve
Available for download

04115 Failure Analysis of a Leaking Slab Valve

Product Number: 51300-04115-SG
ISBN: 04115 2004 CP
Author: Michiel P. Brongers and Gerhardus H. Koch, CC Technologies Inc.; Maher Mustafa Nour, Sante Fe Compan
$20.00
Picture for 08099 New Limits for Sulfide Stress Cracking in Deep Water Applications
Available for download

08099 New Limits for Sulfide Stress Cracking in Deep Water Applications

Product Number: 51300-08099-SG
ISBN: 08099 2008 CP
Author: Russell D. Kane and Pilar Quiroga
Publication Date: 2008
$20.00
Picture for 08120 Corrosion of Natural Gas Transmission Line: a Case Study
Available for download

08120 Corrosion of Natural Gas Transmission Line: a Case Study

Product Number: 51300-08120-SG
ISBN: 08120 2008 CP
Author: Mohammed Javeed Shaikh and Khadir Muhideen
Publication Date: 2008
$20.00