Search
Filters
Close

01317 TELLURIC CURRENT CONSIDERATIONS IN THE CP DESIGN FOR THE MARITIMES AND NORTHEAST PIPELINE

Product Number: 51300-01317-SG
ISBN: 01317 2001 CP
Author: B.C. Rix, D.H. Boteler
$0.00
$20.00
$20.00
The Maritimes and Northeast Pipeline on the east coast of North America is constructed through an area where large geomagnetic disturbances can be expected. Because of this it was decided to include consideration of telluric current effects in the design of the cathodic protection (CP) system for the new pipeline. An evaluation was made of the electric fields expected to be produced by geomagnetic disturbances. A computer model was set up to examine the pipeline response to these electric fields. This allowed calculations of the pipe-to-soil potentials produced with different coating resistances and placement of insulating flanges and groundbeds, which therefore allow various cathodic protection schemes to be evaluated before construction. The modeling showed that putting insulating flanges into the pipe created extra sites where large pipe-to-soil potentials would be produced. Accordingly it was decided to make the pipe electrically continuous and drain the telluric currents off at the ends of the pipeline using potential-controlled rectifiers. This paper describes the CP system installed to mitigate the telluric current effects and presents observations of telluric currents both before and after commissioning of the CP system. Keywords: cathodic protection, telluric currents, geomagnetic disturbances, potential control .
The Maritimes and Northeast Pipeline on the east coast of North America is constructed through an area where large geomagnetic disturbances can be expected. Because of this it was decided to include consideration of telluric current effects in the design of the cathodic protection (CP) system for the new pipeline. An evaluation was made of the electric fields expected to be produced by geomagnetic disturbances. A computer model was set up to examine the pipeline response to these electric fields. This allowed calculations of the pipe-to-soil potentials produced with different coating resistances and placement of insulating flanges and groundbeds, which therefore allow various cathodic protection schemes to be evaluated before construction. The modeling showed that putting insulating flanges into the pipe created extra sites where large pipe-to-soil potentials would be produced. Accordingly it was decided to make the pipe electrically continuous and drain the telluric currents off at the ends of the pipeline using potential-controlled rectifiers. This paper describes the CP system installed to mitigate the telluric current effects and presents observations of telluric currents both before and after commissioning of the CP system. Keywords: cathodic protection, telluric currents, geomagnetic disturbances, potential control .
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 01316 OBSERVATIONS OF TELLURIC CURRENTS
Available for download

01316 OBSERVATIONS OF TELLURIC CURRENTS IN CANADIAN PIPELINES

Product Number: 51300-01316-SG
ISBN: 01316 2002 CP
Author: D.H. Boteler and L. Trichtchenko
$20.00
Picture for 07686 ASSESSING PIPELINE VULNERABILITY TO TELLURIC CURRENTS
Available for download

07686 ASSESSING PIPELINE VULNERABILITY TO TELLURIC CURRENTS

Product Number: 51300-07686-SG
ISBN: 07686 2007 CP
Author: D.H. Boteler
Publication Date: 2007
$20.00
Picture for 01315 STUDIES OF TELLURIC CURRENTS ON
Available for download

01315 STUDIES OF TELLURIC CURRENTS ON PIPELINES IN SOUTHERN SWEDEN

Product Number: 51300-01315-SG
ISBN: 01315 2001 CP
Author: Hans-Erik Edwall, David Boteler
$20.00