Search
Filters
Close

Use of Hygrothermal Models for Understanding Water Transport in Corrosion Under Insulation Application

Thermal insulation is used in operating facilities to conserve heat and protect against freezing amongst others. A consequence of insulating the pipe is the necessity to manage the introduced threat of corrosion under insulation (CUI). For CUI to occur water and oxygen must enter and migrate through the insulation to reach the external surface of the pipe. The water transport characteristics are dependent on several factors such as type of insulation type of jacketing pipe operating temperature external weather water entry/leakage rate and cyclic service. In hot piping there are competing water transport characteristics as in water vapor moves outwards away from the pipe as water enters into insulation. Knowing the water transport and the parameters that influence the time of wetness at the metal surface helps in understanding conditions favoring CUI.The use of transient hygrothermal models for moisture control is well established in the building insulation design codes and standards. The building designs naturally shed the liquid water to minimize entry and facilitate breathing of vapor so that moisture doesn’t accumulate within building. Several building industry hygrothermal models have been developed and are available for commercial use. One such commercial model has been used to understand water transport in a CUI application. The case study involves evaluation of piping and pipeline installed with a closed cell polyurethane insulation. The hygrothermal model provided insights on the parameters influencing the time of wetness and the ease of water escaping the pipe-insulation-jacketing system. Additional results comparing different insulations are also presented.Key words: Corrosion under insulation water transport hygrothermal models building industry polyurethane insulation

Product Number: 51319-13484-SG
Author: Sai Prasanth Venkateswaran
Publication Date: 2019
$0.00
$20.00
$20.00
Also Purchased
Picture for Corrosion Under Insulation Detection Technique
Available for download

51313-02570-Corrosion Under Insulation Detection Technique

Product Number: 51313-02570-SG
ISBN: 02570 2013 CP
Author: Sally Nicola
Publication Date: 2013
$20.00
Picture for 03022 CORROSION UNDER THERMAL INSULATION AND
Available for download

03022 CORROSION UNDER THERMAL INSULATION AND FIREPROOFING AN OVERVIEW

Product Number: 51300-03022-SG
ISBN: 03022 2003 CP
Author: J. F. Delahunt
$20.00
Picture for Test Method for Coatings under Thermal Insulation
Available for download

Test Method for Coatings under Thermal Insulation

Product Number: 51314-4193-SG
ISBN: 4193 2014 CP
Author: Ole Knudsen
Publication Date: 2014
$0.00