Control of external corrosion on buried/submerged metallic piping systems. Electrically insulating coatings. Electrical isolation. Cathodic protection. Interference currents. Historical Document 1983
Or
This NACE Standard Recommended Practice was prepared by NACE Task Group T-10-1, composed of corrosion consultants, corrosion control personnel from oil and gas transmission companies, gas distribution companies, power companies, communications companies, the Federal Energy Regulatory Commission, the National Bureau of Standards, the Department of Transportation, the American Water Works Association, representatives from steel, cast iron, copper, and aluminum piping manufacturers, and coating applicators, manufacturers, and others concerned with corrosion control. The Standard is issued by NACE under the auspices of Group Committee T-10 on Underground Corrosion Control. The purpose of this Recommended Practice is to present procedures and practices for achieving effective control of external corrosion on buried or submerged metallic piping systems. These recommendations are also applicable to many other buried or submerged metallic structures. The Recommended Practice describes the use of electrically insulating coatings, electrical isolation, and cathodic protection as corrosion control methods. It contains specific provisions for the application of cathodic protection to existing bare, existing coated, and new piping systems. Also included are procedures for control of interference currents on pipelines. This Recommended Practice does not include corrosion control methods based on chemical control of the environment or on the use of electrically conductive coatings. Historical Document 1983
We are unable to complete this action. Please try again at a later time.
If this error continues to occur, please contact AMPP Customer Support for assistance.
Use this error code for reference:
Please login to use Standards Credits*
* AMPP Members receive Standards Credits in order to redeem eligible Standards and Reports in the Store
You are not a Member.
AMPP Members enjoy many benefits, including Standards Credits which can be used to redeem eligible Standards and Reports in the Store.
You can visit the Membership Page to learn about the benefits of membership.
You have previously purchased this item.
Go to Downloadable Products in your AMPP Store profile to find this item.
You do not have sufficient Standards Credits to claim this item.
Click on 'ADD TO CART' to purchase this item.
Your Standards Credit(s)
1
Remaining Credits
0
Please review your transaction.
Click on 'REDEEM' to use your Standards Credits to claim this item.
You have successfully redeemed:
Go to Downloadable Products in your AMPP Store Profile to find and download this item.
The purpose of this document is to present information on rail transit stray current as it concerns transit and utility engineers.
The theoretical basis for the 100 millivolt (mV) cathodic polarization criterion. Effects of other factors such as temperature, mill scale, moisture, and anaerobic bacteria, polarization.