Search
Filters
Close

51313-02127-Optimization of Standard Test Method Corrosion Rate with 2-Mercaptobenzothiazole as a Model

Product Number: 51313-02127-SG
ISBN: 02127 2013 CP
Author: tiara lubis
Publication Date: 2013
$0.00
$20.00
$20.00
Corrosion or metal rust is the event of damage or loss of quality. Weight Loss Methods with used Wheel Test determines the corrosion rate based on weight changes before and after the corrosion. Wheel Test is cheap and simple but requires a longer time and require an analytical balance that has a high accuracy the other method Tafel extrapolation and Electrochemical Impedance Spectroscopy can be obtained in a shorter time but this method must consider the geometry of measurement the selection of a suitable test environment and best techniques. In this research the ratio of carbon steel corrosion rate is determined in the acetic acid buffer solution of pH 4-6 at a temperature of 25C 45C and 65C. The research vary the size of the working electrode and auxiliary electrode and the distance between working electrode and auxiliary electrode and the concentration of inhibitor. Results from this research is Inhibitors tested can work effectively at pH 4 and temperatures up to 45C when the size of the working electrode is greater than the auxiliary electrode and the distance between the working electrode with auxiliary electrode is1.2 cm with the diameter working electrode is 1.2 cm and 06 for auxiliary electrode.
Corrosion or metal rust is the event of damage or loss of quality. Weight Loss Methods with used Wheel Test determines the corrosion rate based on weight changes before and after the corrosion. Wheel Test is cheap and simple but requires a longer time and require an analytical balance that has a high accuracy the other method Tafel extrapolation and Electrochemical Impedance Spectroscopy can be obtained in a shorter time but this method must consider the geometry of measurement the selection of a suitable test environment and best techniques. In this research the ratio of carbon steel corrosion rate is determined in the acetic acid buffer solution of pH 4-6 at a temperature of 25C 45C and 65C. The research vary the size of the working electrode and auxiliary electrode and the distance between working electrode and auxiliary electrode and the concentration of inhibitor. Results from this research is Inhibitors tested can work effectively at pH 4 and temperatures up to 45C when the size of the working electrode is greater than the auxiliary electrode and the distance between the working electrode with auxiliary electrode is1.2 cm with the diameter working electrode is 1.2 cm and 06 for auxiliary electrode.
Product tags
Also Purchased
Picture for Hot Corrosion Behavior of Protective Oxide Scales with Sodium Chloride in Chlorine Gas Environment
Available for download

51313-02125-Hot Corrosion Behavior of Protective Oxide Scales with Sodium Chloride in Chlorine Gas Environment

Product Number: 51313-02125-SG
ISBN: 02125 2013 CP
Author: Syed Khalid Hasan
Publication Date: 2013
$20.00
Picture for Internal Corrosion of CO2 Pipelines for Carbon Capture and Storage
Available for download

51313-02133-Internal Corrosion of CO2 Pipelines for Carbon Capture and Storage

Product Number: 51313-02133-SG
ISBN: 02133 2013 CP
Author: Samson Son Sim
Publication Date: 2013
$20.00
Picture for Weld Seam Corrosion of Steel Sprinkler Pipe
Available for download

51313-02140-Weld Seam Corrosion of Steel Sprinkler Pipe

Product Number: 51313-02140-SG
ISBN: 02140 2013 CP
Author: Paul Su
Publication Date: 2013
$20.00