51314-3862-Monitoring of Corrosion Distribution Inside Steel Pipe for Transmission Tower

Product Number: 51314-3862-SG
ISBN: 3862 2014 CP
Author: Atsushi Naganuma
Publication Date: 2014
$0.00
$20.00
$20.00
Degradation of aged power transmission system becomes a serious problem. As for a transmission tower inner corrosion of a steel pipe beam is one of issues because inspection from the external appearance of the pipe is difficult. In order to utilize practical inspection clarification of the corrosion properties of the pipe is required. In this study several atmospheric corrosion sensors (ACM sensors) were place at a regular interval inside the steel pipe which is set up at coastal testing field and time transition of corrosion behavior distribution inner steel pipe from end to center was evaluated. Following results were obtained with this experiment: (1) corrosion behavior inner steel pipe strongly depends on climate condition such as temperature relative humidity and weather (2) corrosion rate tends to become smaller from end to center direction of steel pipe (3) corrosion information acquired from ACM sensors is in good agreement with corrosion condition of steel pipe sample which concludes that the method used in this study is effective for the monitoring of corrosion inner of steel pipe.
Degradation of aged power transmission system becomes a serious problem. As for a transmission tower inner corrosion of a steel pipe beam is one of issues because inspection from the external appearance of the pipe is difficult. In order to utilize practical inspection clarification of the corrosion properties of the pipe is required. In this study several atmospheric corrosion sensors (ACM sensors) were place at a regular interval inside the steel pipe which is set up at coastal testing field and time transition of corrosion behavior distribution inner steel pipe from end to center was evaluated. Following results were obtained with this experiment: (1) corrosion behavior inner steel pipe strongly depends on climate condition such as temperature relative humidity and weather (2) corrosion rate tends to become smaller from end to center direction of steel pipe (3) corrosion information acquired from ACM sensors is in good agreement with corrosion condition of steel pipe sample which concludes that the method used in this study is effective for the monitoring of corrosion inner of steel pipe.
Product tags
Also Purchased
Picture for Monitoring of Corrosion Rate and Evaluation of Deposited Sea Salt Distributed inside Steel Pipe for
Available for download
Picture for Minimizing the Grounding Resistance of Compact Cathodic Protection Anodic Beds with Finite Element M
Available for download

51314-3859-Minimizing the Grounding Resistance of Compact Cathodic Protection Anodic Beds with Finite Element Method

Product Number: 51314-3859-SG
ISBN: 3859 2014 CP
Author: Chengwei Xu
Publication Date: 2014
$20.00
Picture for The Laboratory Evaluation of Seawater Injection on H2S Production Incorporating Several Different T
Available for download