Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

51314-3859-Minimizing the Grounding Resistance of Compact Cathodic Protection Anodic Beds with Finite Element Method

Product Number: 51314-3859-SG
ISBN: 3859 2014 CP
Author: Chengwei Xu
Publication Date: 2014
$0.00
$20.00
$20.00
A more flexible grounding resistance calculation method based on finite element analysis (FEA) method is suggested which is especially suitable for calculating grounding resistance of cathodic protection (CP) anodic bed. Traditional cathodic protection anodic bed grounding resistance calculation method mainly based on ideal theoretical equation can only be applied for the cases with each anode rod lining in a straight line. But the FEA method can be used in calculating grounding resistance of anodic bed at any arrangement. Moreover a realistic soil resistivity usually varying with depth can be included in numerical model. The detailed steps for this numerical method can be detailed as follow: building a 3D geometric model according to general design meshing the geometric model setting reasonable boundary conditions solving and post-solving the grounding resistance with ohmic law. To further explain this procedure a realistic CP anodic bed design project is presented designing a compact anodic bed within a limited area (5m×30m). Firstly a compact anodic bed design pattern with 14 anode rods in two parallel lines (2×7) is calculated with FEA method. The results show that this design can not meet the grounding resistance target. Another 4 designs with anode rods arranged as 2×6 2×8 2×9 3×6 are calculated respectively. Finally the design l2×8 is recommended from the view of economy and practicability. 
A more flexible grounding resistance calculation method based on finite element analysis (FEA) method is suggested which is especially suitable for calculating grounding resistance of cathodic protection (CP) anodic bed. Traditional cathodic protection anodic bed grounding resistance calculation method mainly based on ideal theoretical equation can only be applied for the cases with each anode rod lining in a straight line. But the FEA method can be used in calculating grounding resistance of anodic bed at any arrangement. Moreover a realistic soil resistivity usually varying with depth can be included in numerical model. The detailed steps for this numerical method can be detailed as follow: building a 3D geometric model according to general design meshing the geometric model setting reasonable boundary conditions solving and post-solving the grounding resistance with ohmic law. To further explain this procedure a realistic CP anodic bed design project is presented designing a compact anodic bed within a limited area (5m×30m). Firstly a compact anodic bed design pattern with 14 anode rods in two parallel lines (2×7) is calculated with FEA method. The results show that this design can not meet the grounding resistance target. Another 4 designs with anode rods arranged as 2×6 2×8 2×9 3×6 are calculated respectively. Finally the design l2×8 is recommended from the view of economy and practicability. 
Product tags
Also Purchased
Picture for 04045 Cathodic Protection Current Requirements for
Available for download

04045 Cathodic Protection Current Requirements for Electrical Grounding Materials

Product Number: 51300-04045-SG
ISBN: 04045 2004 CP
Author: Robert A. Gummow, Corrosion Service Co. Ltd.
$20.00
Picture for 01601 MITIGATION DESIGN, INSTALLATION AND POST
Available for download

01601 MITIGATION DESIGN, INSTALLATION AND POST COMMISSIONING MEASUREMENTS FOR A PIPELINE COLLOCATED WITH AC TRANSMISSION LINES

Product Number: 51300-01601-SG
ISBN: 01601 2001 CP
Author: John Dabkowski, Robert F. Allen, Frank A. Perry
$20.00