Long-term monitoring of galvanic anodes installed in reinforced concrete structures has provided the data required to better understand long-term anode performance. Detailed analysis of field and laboratory performance data has identified an aging pattern which follows an exponential decrease in current output similar to a 'half-life' principle where current is halved at constant periods of time. A predictive model has been developed to describe anode current output over time. The predictive model which includes an "aging-factor" can be determined for any galvanic anode. The aging-factor is primarily dependent on the activating chemistry of the anode. The aging-factor also depends on the relative surface area of the anode compared to the surface area of steel wherein the harder an anode works early on in its life the worse its aging-factor becomes.

The predictive model which is based on long-term field data allows galvanic anode systems to be designed to meet any desired performance criteria at any point in time.  The model may also be used to design galvanic cathodic protection systems to provide specifiable long-term current density and more controlled polarization to the steel.

Long-term monitoring of galvanic anodes installed in reinforced concrete structures has provided the data required to better understand long-term anode performance. Detailed analysis of field and laboratory performance data has identified an aging pattern which follows an exponential decrease in current output similar to a 'half-life' principle where current is halved at constant periods of time. A predictive model has been developed to describe anode current output over time. The predictive model which includes an "aging-factor" can be determined for any galvanic anode. The aging-factor is primarily dependent on the activating chemistry of the anode. The aging-factor also depends on the relative surface area of the anode compared to the surface area of steel wherein the harder an anode works early on in its life the worse its aging-factor becomes.

The predictive model which is based on long-term field data allows galvanic anode systems to be designed to meet any desired performance criteria at any point in time.  The model may also be used to design galvanic cathodic protection systems to provide specifiable long-term current density and more controlled polarization to the steel.

Also Purchased
Picture for 96063 GALVANIC CORROSION IN OIL AND GAS
Available for download

96063 GALVANIC CORROSION IN OIL AND GAS ENVIRONMENTS

Product Number: 51300-96063-SG
ISBN: 96063 1996 CP
Author: H. Kaneta, T. Hara, H. Asahi
$20.00
Picture for 09274 Galvanic Corrosion Inhibition: Validation of Simple Laboratory Testing
Available for download

09274 Galvanic Corrosion Inhibition: Validation of Simple Laboratory Testing

Product Number: 51300-09274-SG
ISBN: 09274 2009 CP
Author: Luca A. Nolasco, Andrew MacDonald and Hongbin (Victor) Wang
Publication Date: 2009
$20.00