Recent close-interval potential surveys have raised concerns about the accuracy of potential measurements on older, poorly-coated pipelines. Two sources of error were identified: metallic IR-drops and equalization currents.
Recent close-interval potential surveys have raised concerns about the accuracy of potential measurements on some older, poorly-coated pipelines. Two significant sources of error were identified: metallic IR-drops and equalization currents. These resulted in measured on and off potentials which differed by hundreds of millivolts from the true potentials, even though the measurements were conducted in accordance with industry best practice.
Examples of these phenomena will be discussed and the electrical theory will be explained. Both interrupted test post surveys and close-interval potential surveys are susceptible and these errors can be difficult to detect. This can have a significant impact on interpretation of survey data, External Corrosion Direct Assessments, and remedial program decisions.
Guidance for identifying when these issues may be relevant and methods for detecting and compensating for these issues will be provided.
Key words: close-interval potential survey, CIPS, CIS, ECDA, equalization current, IR free, measurement error, metallic IR drop.
Methods for dealing with sources of errors affecting the accuracy of the Direct Current Voltage Gradient (DCVG) coating defect identification and sizing tool.
We are unable to complete this action. Please try again at a later time.
If this error continues to occur, please contact AMPP Customer Support for assistance.
Error Message:
Please login to use Standards Credits*
* AMPP Members receive Standards Credits in order to redeem eligible Standards and Reports in the Store
You are not a Member.
AMPP Members enjoy many benefits, including Standards Credits which can be used to redeem eligible Standards and Reports in the Store.
You can visit the Membership Page to learn about the benefits of membership.
You have previously purchased this item.
Go to Downloadable Products in your AMPP Store profile to find this item.
You do not have sufficient Standards Credits to claim this item.
Click on 'ADD TO CART' to purchase this item.
Your Standards Credit(s)
1
Remaining Credits
0
Please review your transaction.
Click on 'REDEEM' to use your Standards Credits to claim this item.
You have successfully redeemed:
Go to Downloadable Products in your AMPP Store Profile to find and download this item.
New tools for data acquisition and display for the field surveyor, data analyst and pipeline operator as they affect Close Interval Potential Surveys (CIPS) and Direct Current Voltage Gradient (DCVG) surveys