Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

51312-01626-Effect of Sensitization on Corrosion Fatigue Crack Propagation of 304 Stainless Steel in 3.5% NaCl

Product Number: 51312-01626-SG
ISBN: 01626 2012 CP
Author: Zuhair Gasem
Publication Date: 2012
$0.00
$20.00
$20.00
AISI 304 type stainless steel is widely used in engineering applications due to its high corrosion resistance associated with Cr addition. Many stainless steels structures such as pipes and pressure vessels are subject to fatigue loading during service operation. The main objective of this research is to investigate the effect of loading frequency on the kinetics of fatigue crack propagation of 304 stainless steel exposed to 3.5% NaCl solution. Two microstructures are examined: annealed and sensitized 304 stainless steels. Sensitization is known to reduce the corrosion resistance of stainless steels and lead to intergranular corrosion. Sensitization is performed at 680°C for 8 hours. Fatigue testing will be carried out according to ASTM E-647 standard using a compact testing type (CT) specimen. The results of this study will be presented with emphasis on the role of sensitization on the cracking processes of stainless steels.
AISI 304 type stainless steel is widely used in engineering applications due to its high corrosion resistance associated with Cr addition. Many stainless steels structures such as pipes and pressure vessels are subject to fatigue loading during service operation. The main objective of this research is to investigate the effect of loading frequency on the kinetics of fatigue crack propagation of 304 stainless steel exposed to 3.5% NaCl solution. Two microstructures are examined: annealed and sensitized 304 stainless steels. Sensitization is known to reduce the corrosion resistance of stainless steels and lead to intergranular corrosion. Sensitization is performed at 680°C for 8 hours. Fatigue testing will be carried out according to ASTM E-647 standard using a compact testing type (CT) specimen. The results of this study will be presented with emphasis on the role of sensitization on the cracking processes of stainless steels.
Product tags
Also Purchased
Picture for Material Selection and Corrosion Control for Topside Process and Utility Piping and Equipment
Available for download

51312-01632-Material Selection and Corrosion Control for Topside Process and Utility Piping and Equipment

Product Number: 51312-01632-SG
ISBN: 01632 2012 CP
Author: Felipe A. Ramirez
Publication Date: 2012
$20.00
Picture for Prediction of Dissolver Lifetimes Through Non-Destructive Evaluation and Laboratory Testing
Available for download

51312-01628-Prediction of Dissolver Lifetimes Through Non-Destructive Evaluation and Laboratory Testing

Product Number: 51312-01628-SG
ISBN: 01628 2012 CP
Author: John I. Mickalonis
Publication Date: 2012
$20.00
Picture for Pilot Scale Application of a Rapid Instantaneous Corrosion Rate Monitoring System
Available for download

51312-01624-Pilot Scale Application of a Rapid Instantaneous Corrosion Rate Monitoring System

Product Number: 51312-01624-SG
ISBN: 01624 2012 CP
Author: Mahbuboor Rahman Choudhury
Publication Date: 2012
$20.00