Search
Filters
Close

Celebrate World Corrosion Awareness Day with 20% off eCourses and eBooks with code WCAD2024 at checkout!

51316-7153-Degradation of FBE Coating on Pipelines in the Presence of Alternating Current Interference

Product Number: 51316-7153-SG
ISBN: 7153 2016 CP
Author: Frank Cheng
Publication Date: 2016
$0.00
$20.00
$20.00
Buried pipelines are protected from external corrosion attack by coating and cathodic protection (CP). When the pipeline is adjacent to the high-voltage power transmission lines it would experienceaccelerated corrosion and reduced CP effectiveness due to the alternating current (AC) interference. There have been extensive works conducted to study AC corrosion of pipelines and the new CP design. However there has been limited work to investigate the effect of AC on coating properties and its performance degradation.In this work the effect of AC on the properties and performance of a fusion bonded epoxy (FBE) coating was studied in a simulated soil solution. Fourier Transform-Infrared Spectroscopy (FT-IR) was used to characterize the structures of the coating that is under various AC current densities. At the same time the water uptaking ionic permeation adhesion and corrosion resistance of the coating upon AC applicationwere studied by a combination of surface analysis techniques such as scanning electron microscope and atomic force microscope and electrochemical impedance measurements. It is anticipated that a complete understanding of the effect of AC interference on coating performance and thus the pipeline corrosion protection is developed.
Buried pipelines are protected from external corrosion attack by coating and cathodic protection (CP). When the pipeline is adjacent to the high-voltage power transmission lines it would experienceaccelerated corrosion and reduced CP effectiveness due to the alternating current (AC) interference. There have been extensive works conducted to study AC corrosion of pipelines and the new CP design. However there has been limited work to investigate the effect of AC on coating properties and its performance degradation.In this work the effect of AC on the properties and performance of a fusion bonded epoxy (FBE) coating was studied in a simulated soil solution. Fourier Transform-Infrared Spectroscopy (FT-IR) was used to characterize the structures of the coating that is under various AC current densities. At the same time the water uptaking ionic permeation adhesion and corrosion resistance of the coating upon AC applicationwere studied by a combination of surface analysis techniques such as scanning electron microscope and atomic force microscope and electrochemical impedance measurements. It is anticipated that a complete understanding of the effect of AC interference on coating performance and thus the pipeline corrosion protection is developed.
Product tags
Also Purchased
Picture for Non-Osmotic Blistering Mechanism in FBE Coatings
Available for download

51312-01298-Non-Osmotic Blistering Mechanism in FBE Coatings

Product Number: 51312-01298-SG
ISBN: 01298 2012 CP
Author: King Him Lo
Publication Date: 2012
$20.00