Search
Filters
Close

Use code FLASH20 at checkout for 20% off all eBooks and eCourses

51315-5449-Comparison of the Corrosion Protection Effectiveness of Vapor Corrosion Inhibitors and Dry Air Systems

Product Number: 51315-5449-SG
ISBN: 5449 2015 CP
Author: Behzad Bavarian
Publication Date: 2015
$0.00
$0.00
$0.00
Corrosion behavior of carbon steel and galvanized steel samples was investigated using two different protection mechanisms: vapor corrosion inhibitor (10% VCI) and constant flow of dry air (RH% <40%) system. The objective of this project was to demonstrate which technique provides more protection in corrosive environments.Corrosion behaviors of carbon steel and galvanized steel samples were studied in two different conditions; the first environment contained 200 ppm chloride solution + 10% vapor phase corrosion inhibitor (VCI) addition the second test environment included 200 ppm chloride solution (injected into environment every 48 hours) with a constant flow of dry air with less than 40%RH at 20 psi applied pressure. The corrosion rate of the exposed samples were monitored for more than six months (~4300 hours) using electrical resistance (ER) probe techniques.The corrosion data have demonstrated that vapor phase corrosion inhibitors have superior advantages over the dry air system. Samples that were exposed in dry air system showed corrosion attack and red rust formation after 21 days of exposure. ER probes showed a corrosion rate of <0.08 mpy for VCI treated while the dry air samples showed a 1.1-1.3 mpy corrosion rate and ER probes were heavily corroded.
Corrosion behavior of carbon steel and galvanized steel samples was investigated using two different protection mechanisms: vapor corrosion inhibitor (10% VCI) and constant flow of dry air (RH% <40%) system. The objective of this project was to demonstrate which technique provides more protection in corrosive environments.Corrosion behaviors of carbon steel and galvanized steel samples were studied in two different conditions; the first environment contained 200 ppm chloride solution + 10% vapor phase corrosion inhibitor (VCI) addition the second test environment included 200 ppm chloride solution (injected into environment every 48 hours) with a constant flow of dry air with less than 40%RH at 20 psi applied pressure. The corrosion rate of the exposed samples were monitored for more than six months (~4300 hours) using electrical resistance (ER) probe techniques.The corrosion data have demonstrated that vapor phase corrosion inhibitors have superior advantages over the dry air system. Samples that were exposed in dry air system showed corrosion attack and red rust formation after 21 days of exposure. ER probes showed a corrosion rate of <0.08 mpy for VCI treated while the dry air samples showed a 1.1-1.3 mpy corrosion rate and ER probes were heavily corroded.
Product tags
Also Purchased
Picture for Comparison of the Corrosion Protection Effectiveness of Vapor Corrosion Inhibitor and Nitrogen Blank
Available for download

51315-5450-Comparison of the Corrosion Protection Effectiveness of Vapor Corrosion Inhibitor and Nitrogen Blanketing System

Product Number: 51315-5450-SG
ISBN: 5450 2015 CP
Author: Behzad Bavarian
Publication Date: 2015
$0.00
Picture for 04418 Performance and Testing of Vapor
Available for download

04418 Performance and Testing of Vapor Phase Corrosion Inhibitors

Product Number: 51300-04418-SG
ISBN: 04418 2004 CP
Author: Alla Y. Furman, Margarita Kharshan, and Christophe J. Chandler, Cortec Corp.
$20.00
Picture for Corrosion of a Vertical Shell and Tube Heat Exchanger
Available for download

51315-5473-Corrosion of a Vertical Shell and Tube Heat Exchanger

Product Number: 51315-5473-SG
ISBN: 5473 2015 CP
Author: Jeffrey Xie
Publication Date: 2015
$0.00