Search
Filters
Close

Celebrate World Corrosion Awareness Day with 20% off eCourses and eBooks with code WCAD2024 at checkout!

51315-5537-Coatings in Combination with Cathodic Protection—Field Experiences after 20+ Years

Product Number: 51315-5537-SG
ISBN: 5537 2015 CP
Author: Ole Knudsen
Publication Date: 2015
$0.00
$0.00
$0.00
By application of coatings on subsea structures the amount of anodes to be installed for cathodic protection (CP) can be decreased. The number of anodes is mainly defined by the lifetime of the structure and the bare metal surface to be protected. An equation is used to estimate the breakdown of the coating as function of time. This equation was developed for projects with a typical lifetime of 20-25 years and without any experience from structures that have been exposed for long lives. The objective with this study was to evaluate coating degradation on subsea offshore installations after long term exposure of coatings on offshore structures and to suggest a revised coating breakdown equation for use in CP design.Four different installations each with more than 20 years exposure time have been investigated; two subsea templates and two jackets. One of the templates has been taken to shore and was investigated there. For the three other installations the condition of the coating has been evaluated based on subsea survey reports. The condition of the coating on the investigated structures shows that the coating breakdown models used in NORSOK M-503 and DNV RP-B-401 are very conservative. However the anode consumption on the installations is higher than the coating degradation would predict. Hence it seems that other parameters in the CP design rules are non-conservative. One possible explanation is that the anode auto-corrosion is underestimated so that too high anode capacities are used in the CP design.
By application of coatings on subsea structures the amount of anodes to be installed for cathodic protection (CP) can be decreased. The number of anodes is mainly defined by the lifetime of the structure and the bare metal surface to be protected. An equation is used to estimate the breakdown of the coating as function of time. This equation was developed for projects with a typical lifetime of 20-25 years and without any experience from structures that have been exposed for long lives. The objective with this study was to evaluate coating degradation on subsea offshore installations after long term exposure of coatings on offshore structures and to suggest a revised coating breakdown equation for use in CP design.Four different installations each with more than 20 years exposure time have been investigated; two subsea templates and two jackets. One of the templates has been taken to shore and was investigated there. For the three other installations the condition of the coating has been evaluated based on subsea survey reports. The condition of the coating on the investigated structures shows that the coating breakdown models used in NORSOK M-503 and DNV RP-B-401 are very conservative. However the anode consumption on the installations is higher than the coating degradation would predict. Hence it seems that other parameters in the CP design rules are non-conservative. One possible explanation is that the anode auto-corrosion is underestimated so that too high anode capacities are used in the CP design.
Product tags
Also Purchased
Picture for 01512 CURRENT DEMAND FOR CATHODIC PROTECTION
Available for download

01512 CURRENT DEMAND FOR CATHODIC PROTECTION OF COATED STEEL - 5 YEARS DATA

Product Number: 51300-01512-SG
ISBN: 01512 2001 CP
Author: Ole Oystein Knudsen and Unni Steinsmo
$20.00
Picture for 00680 COATING QUALITY IN CP/COATING SYSTEMS
Available for download

00680 COATING QUALITY IN CP/COATING SYSTEMS - COMPARISON OF ACCELERATED TEST AND LONG TIME EXPOSURE

Product Number: 51300-00680-SG
ISBN: 00680 2000 CP
Author: Unni Steinsmo, Marit Bjordal, Ole Oystein Knudsen and Tone Solem
$20.00
Picture for Coating Failure Incidents on the Norwegian Continental Shelf Since the Introduction of NORSOK M-501
Available for download

51313-02500-Coating Failure Incidents on the Norwegian Continental Shelf Since the Introduction of NORSOK M-501

Product Number: 51313-02500-SG
ISBN: 02500 2013 CP
Author: Ole Knudsen
Publication Date: 2013
$20.00