Corrosion has long been recognized as an extremely costly naturally occurring phenomenon that can be controlled through the proper application of corrosion prevention and control methods protecting public safety, extending the service life of assets and preventing damage to property and the environment. The landmark Cost of Corrosion Study published by the U.S. Federal Highway Administration estimated that corrosion costs were approximately 3.1% of the nation’s GDP. Within the study, several key sectors of the US economy were studied. This paper is focused on one of those areas – the corrosion risks associated with storage tanks that contain hazardous materials. The study determined that the annual direct cost of corrosion for above ground hazardous material storage tanks (ASTs) in the US was ~$4.5 billion.
This case study details the retrofit installation of a replaceable linear anode based impressed current cathodic protection for a critical service double wall cryogenic Ethylene Storage Tank in Kuwait. The ground bed underneath the tank bottom has been provided with the heaters to maintain the temperature of soil, preventing the ice film formation below the tank bottom. This critical service tank could not be taken out of service and the existing CP system consisting of discreet anodes around the perimeter of the tank proved ineffective in meeting NACE criteria for cathodic protection. Utilizing Horizontal Directional Drilling (HDD) to bore under the tank, offered the opportunity to install directly below the tank linear anodes and a portable reference electrode profile tube while remaining in service. This novel approach to installing cathodic protection on existing tanks offers several critical benefits but had not previously b een attempted in the Middle East Region. This paper will discuss the lessons learned in bringing this technology to the Middle East Region and focus on the design process, the installation works including the use of advanced electronic tracking technology for the HDD bore, and the commissioning results.
In this paper, the CP current distribution with changing resistivities and the area of influence required to meet effective CP criteria, is studied. The results indicate that the tank pad electrolyte resistivity plays a significant role in achieving uniform CP current distribution. The paper also explores the use of Vapor Corrosion Inhibitor (VCI) and its effect on electrolyte resistivity and the resulting CP current distribution.
We are unable to complete this action. Please try again at a later time.
If this error continues to occur, please contact AMPP Customer Support for assistance.
Error Message:
Please login to use Standards Credits*
* AMPP Members receive Standards Credits in order to redeem eligible Standards and Reports in the Store
You are not a Member.
AMPP Members enjoy many benefits, including Standards Credits which can be used to redeem eligible Standards and Reports in the Store.
You can visit the Membership Page to learn about the benefits of membership.
You have previously purchased this item.
Go to Downloadable Products in your AMPP Store profile to find this item.
You do not have sufficient Standards Credits to claim this item.
Click on 'ADD TO CART' to purchase this item.
Your Standards Credit(s)
1
Remaining Credits
0
Please review your transaction.
Click on 'REDEEM' to use your Standards Credits to claim this item.
You have successfully redeemed:
Go to Downloadable Products in your AMPP Store Profile to find and download this item.
Cathodic protection of hot tank bottom tanks requires specific design parameters. This paper presents the design, installation details and commissioning results for two hot sulphur tank cathodic protection using impressed current titanium / Mixed Metal Oxide ribbon anode grid system.
Soil-side corrosion of the bottom plates of aboveground storage tanks is the main cause of tank failure. A case study is discussed in this paper, in which failures of three storage tanks were investigated. Soil analysis revealed high salt content and low resistivity.