Search
Filters
Close

51313-02588-Biofouling Control Program for Open Recirculating Cooling System with Chiller to Reduce Costs

Product Number: 51313-02588-SG
ISBN: 02588 2013 CP
Author: naohiro nagai
Publication Date: 2013
$0.00
$20.00
$20.00

     Various biofouling control chemicals have been commonly applied to open recirculating cooling water systems with refrigerators at industrial factories and buildings to keep system performance at higher level and to reduce the risk of waterborne deceases such as Legionnaire’s disease. The biofouling control chemicals can be classified to two types of oxidizing and non-oxidizing but deterioration of chemicals’ performance can’t be evitable due to active ingredients’ decomposition and/or adsorption to other substances.
     New biofouling control program has been developed which consists of three technologies the advanced stabilized oxidizing chemical regeneration of active ingredients and efficiency monitoring for refrigerator. Because the new program has the superior performance to suppress the biofouling in the whole system including refrigerator recirculating lines and cooling tower the increase of electricity consumption can be depressed and the time interval of system cleaning can be prolonged.
    Filed applications show the improvement of energy efficiency of the refrigerators up to 10% compared to the previous chemicals treatments. One case at an electric industry factory shows 9% of energy efficiency improvement that can be estimated to the decrease of CO2 emission of 1900 t.
 

     Various biofouling control chemicals have been commonly applied to open recirculating cooling water systems with refrigerators at industrial factories and buildings to keep system performance at higher level and to reduce the risk of waterborne deceases such as Legionnaire’s disease. The biofouling control chemicals can be classified to two types of oxidizing and non-oxidizing but deterioration of chemicals’ performance can’t be evitable due to active ingredients’ decomposition and/or adsorption to other substances.
     New biofouling control program has been developed which consists of three technologies the advanced stabilized oxidizing chemical regeneration of active ingredients and efficiency monitoring for refrigerator. Because the new program has the superior performance to suppress the biofouling in the whole system including refrigerator recirculating lines and cooling tower the increase of electricity consumption can be depressed and the time interval of system cleaning can be prolonged.
    Filed applications show the improvement of energy efficiency of the refrigerators up to 10% compared to the previous chemicals treatments. One case at an electric industry factory shows 9% of energy efficiency improvement that can be estimated to the decrease of CO2 emission of 1900 t.
 

Product tags
Also Purchased
Picture for Top of Line Corrosion with High CO2 and Organic Acid
Available for download

51313-02591-Top of Line Corrosion with High CO2 and Organic Acid

Product Number: 51313-02591-SG
ISBN: 02591 2013 CP
Author: Gaute Svenningsen
Publication Date: 2013
$20.00
Picture for Evaluating Inhibitor Performance in CO2-Saturated Erosion-Corrosion Environments
Available for download

51313-02585-Evaluating Inhibitor Performance in CO2-Saturated Erosion-Corrosion Environments

Product Number: 51313-02585-SG
ISBN: 02585 2013 CP
Author: Richard Barker
Publication Date: 2013
$20.00
Picture for Development of Sour Service Offshore High Strength and Heavy Wall Line Pipe DSAW Process
Available for download

51313-02580-Development of Sour Service Offshore High Strength and Heavy Wall Line Pipe DSAW Process

Product Number: 51313-02580-SG
ISBN: 02580 2013 CP
Author: Tribhuwan Kathayat
Publication Date: 2013
$20.00