Pipelines collocated in close proximity to high voltage alternating current (HVAC) transmission lines may be subjected to electrical interference from capacitive electromagnetic inductive and conductive effects. If these effects are high enough they may pose a safety hazard to personnel or may compromise the integrity of the pipeline. The effects of HVAC interference from a personnel safety and corrosion risk are well documented however recent developments in the electric power transmission industry have driven trends toward increasing HVAC transmission line voltages and currents. Renewable energy generation and corresponding technologies have shown rapid growth in recent years. Many factors are driving the generating facilities be it wind hydro-electric solar or other further from the major consumption centers requiring the power. This creates a well-documented challenge for efficient electric power transmission over increasing distances. Multiple technologies have been developed recently to help overcome long distance transmission line loss each having its own unique detriments. However nearly all involve significant increases to the transmission line operating capacity and will result in elevated line currents whether they are short term dynamic loads or steady state. The increasing HVAC transmission currents coupled with the increasing trend toward sharing right-of-way (ROW) access present challenges for the pipeline industry. This paper focuses on reviewing the recent trends in the HVAC transmission industry and their effects on collocated buried pipelines specific to induced AC potentials current density and ground fault hazards.
Pipelines collocated in close proximity to high voltage alternating current (HVAC) transmission lines may be subjected to electrical interference from capacitive electromagnetic inductive and conductive effects. If these effects are high enough they may pose a safety hazard to personnel or may compromise the integrity of the pipeline. The effects of HVAC interference from a personnel safety and corrosion risk are well documented however recent developments in the electric power transmission industry have driven trends toward increasing HVAC transmission line voltages and currents. Renewable energy generation and corresponding technologies have shown rapid growth in recent years. Many factors are driving the generating facilities be it wind hydro-electric solar or other further from the major consumption centers requiring the power. This creates a well-documented challenge for efficient electric power transmission over increasing distances. Multiple technologies have been developed recently to help overcome long distance transmission line loss each having its own unique detriments. However nearly all involve significant increases to the transmission line operating capacity and will result in elevated line currents whether they are short term dynamic loads or steady state. The increasing HVAC transmission currents coupled with the increasing trend toward sharing right-of-way (ROW) access present challenges for the pipeline industry. This paper focuses on reviewing the recent trends in the HVAC transmission industry and their effects on collocated buried pipelines specific to induced AC potentials current density and ground fault hazards.
Product tags
Also Purchased
Picture for 09541 Effect of Alternating Current by High Power Lines Voltage and Electric Transmission Systems in
Available for download

09542 Effect of Alternating Current by High Power Lines Voltage and Electric Transmission Systems in Pipelines Corrosion

Product Number: 51300-09541-SG
ISBN: 09541 2009 CP
Author: Neusvaldo Lira de Almeid, Diogo Lima Silva, Eduardo W. Laurino, Gutemberg Souza Pimenta, Mario Leite
Publication Date: 2009
$20.00
Picture for Bio-Oil Properties and Effects on Containment Materials
Available for download

51314-4423-Bio-Oil Properties and Effects on Containment Materials

Product Number: 51314-4423-SG
ISBN: 4423 2014 CP
Author: James Keiser
Publication Date: 2014
$20.00