Search
Filters
Close

Celebrate World Corrosion Awareness Day with 20% off eCourses and eBooks with code WCAD2024 at checkout!

51313-02340-Accurate Determination of KIapplied for NACE Standard TM0177 Method D Test

Product Number: 51313-02340-SG
ISBN: 02340 2013 CP
Author: Florian Thebault
Publication Date: 2013
$0.00
$20.00
$20.00

NACE TM0177 Method D (DCB) test allows the determination of the critical stress intensity factor KISSC below which the propagation of a sulfide stress crack in the material is stopped. For a given severity of the sour medium (pH PH2S T [Cl-]…) KISSC is not a material constant since it depends for instance on the testing arm displacement. Recently the Klimit concept was proposed to circumvent this issue. Klimit is a conservative KISSC value and would be more representative of the material corrosion resistance. For an accurate determination of Klimit it is necessary to know KIapplied the KI value when the test starts. In the proposed revision of the NACE TM0177 standard it is recommended to use the compliance of the DCB specimen and the calculated arm displacement value for the determination of KIapplied.

This work is dedicated to checkout the methodology to calculate KIapplied values. Experimental measurements of the initial compliance of chevron notched specimens (before the SSC crack propagation) have been performed assisted by a numerical model of the DCB specimen. The validity of the compliance equation for the wedge insertion the necessity to correct the lift-off load value for the compensation of the wedge compression and the definition that should apply for the initial crack length are discussed. Recommendations for an accurate determination of KIapplied values are then proposed.
 

NACE TM0177 Method D (DCB) test allows the determination of the critical stress intensity factor KISSC below which the propagation of a sulfide stress crack in the material is stopped. For a given severity of the sour medium (pH PH2S T [Cl-]…) KISSC is not a material constant since it depends for instance on the testing arm displacement. Recently the Klimit concept was proposed to circumvent this issue. Klimit is a conservative KISSC value and would be more representative of the material corrosion resistance. For an accurate determination of Klimit it is necessary to know KIapplied the KI value when the test starts. In the proposed revision of the NACE TM0177 standard it is recommended to use the compliance of the DCB specimen and the calculated arm displacement value for the determination of KIapplied.

This work is dedicated to checkout the methodology to calculate KIapplied values. Experimental measurements of the initial compliance of chevron notched specimens (before the SSC crack propagation) have been performed assisted by a numerical model of the DCB specimen. The validity of the compliance equation for the wedge insertion the necessity to correct the lift-off load value for the compensation of the wedge compression and the definition that should apply for the initial crack length are discussed. Recommendations for an accurate determination of KIapplied values are then proposed.
 

Product tags
Also Purchased
Picture for 11098 KLimit in NACE TM0177 - Method D (DCB): Definition, Measurement and Use
Available for download

11098 KLimit in NACE TM0177 - Method D (DCB): Definition, Measurement and Use

Product Number: 51300-11098-SG
ISBN: 11098 2011 CP
Author: K. E. Szklarz
Publication Date: 2011
$20.00
Picture for Klimit of C110 in NACE TM0177 Solution A: Influence of the Specimen Size and the Initial Crack Lengt
Available for download

51314-3822-K(limit) of C110 in NACE TM0177 Solution A: Influence of the Specimen Size and the Initial Crack Length

Product Number: 51314-3822-SG
ISBN: 3822 2014 CP
Author: Florian Thebault
Publication Date: 2014
$0.00
Picture for Assessing Interference Between Sacrificial Anodes on Anode Sleds
Available for download

51313-02344-Assessing Interference Between Sacrificial Anodes on Anode Sleds

Product Number: 51313-02344-SG
ISBN: 02344 2013 CP
Author: Tim Froome
Publication Date: 2013
$20.00