Search
Filters
Close

Celebrate World Corrosion Awareness Day with 20% off eCourses and eBooks with code WCAD2024 at checkout!

99586 THE EFFECT OF BUFFERED SOLUTIONS IN CORROSION TESTING OF ALLOYED 13 % Cr MARTENSITIC STAINLESS STEELS FOR MILDLY SOUR APPLICATIONS

Product Number: 51300-99586-SG
ISBN: 99586 1999 CP
Author: Jakob Enerhaug, John M. DrugIi, Trend Rogne, Morten Svenning and Sten Axelsen
$0.00
$20.00
$20.00
13 % Cr stainless steels may suffer from sulphide stress corrosion cracking in sour environments if hydrogen enters the material. Hydrogen evolution is caused by the cathodic reaction in the corrosion process. As distinct from solutions without buffer, buffered solutions keep the pH stable at the surface almost independent of the electrochemical reactions. The most common initiation process for corrosion of stainless steels is break-down of the passive oxide by subsequent local acidification, which to a certain extent can be prevented in buffered solutions. For local corrosion the risk of corrosion therefore is higher in solutions without buffer than in buffered solutions at the same bulk pH. Hydrogen evolution may also be caused by general corrosion. For this type of corrosion the effect of buffer in the solution may be, contrary to the effect for local corrosion, that general corrosion of 13 Cr (with risk for cracking of loaded specimens) is more readily initiated in buffered solutions than in solutions without buffer at the same pH. With respect to corrosion on ground alloyed 13 Cr base material by coupling to carbon steel, it is shown that gen;ral corrosion initiates both in strongly and moderately without buffer at pH 3.5. Keywords: Alloyed 13 Chromium steels, corrosion, simulated condensed water. welds, buffer, CO2/H2S buffered solutions, but not in solution gas mixture, active corrosion, galvanic
13 % Cr stainless steels may suffer from sulphide stress corrosion cracking in sour environments if hydrogen enters the material. Hydrogen evolution is caused by the cathodic reaction in the corrosion process. As distinct from solutions without buffer, buffered solutions keep the pH stable at the surface almost independent of the electrochemical reactions. The most common initiation process for corrosion of stainless steels is break-down of the passive oxide by subsequent local acidification, which to a certain extent can be prevented in buffered solutions. For local corrosion the risk of corrosion therefore is higher in solutions without buffer than in buffered solutions at the same bulk pH. Hydrogen evolution may also be caused by general corrosion. For this type of corrosion the effect of buffer in the solution may be, contrary to the effect for local corrosion, that general corrosion of 13 Cr (with risk for cracking of loaded specimens) is more readily initiated in buffered solutions than in solutions without buffer at the same pH. With respect to corrosion on ground alloyed 13 Cr base material by coupling to carbon steel, it is shown that gen;ral corrosion initiates both in strongly and moderately without buffer at pH 3.5. Keywords: Alloyed 13 Chromium steels, corrosion, simulated condensed water. welds, buffer, CO2/H2S buffered solutions, but not in solution gas mixture, active corrosion, galvanic
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 99585 EFFECT OF TEST SOLUTION COMPOSITIONS ON
Available for download
Picture for 00130 Effects of pH and PH2S on SSC Resistance of
Available for download

00130 Effects of pH and PH2S on SSC Resistance of Martensitic Stainless Steels

Product Number: 51300-00130-SG
ISBN: 00130 2000 CP
Author: Shuji HASHIZUME, Yasuto INOHARA and Katsumi MASAMURA
$20.00