99430 INVESTIGATION OF THE SUSCEPTIBILITY OF CONVENTIONAL ASTM A5 16-70 PRESSURE VESSEL STEEL TO HIC AND SOHIC IN H2S-CONTAINING DGA SOLUTIONS

Product Number: 51300-99430-SG
ISBN: 99430 1999 CP
Author: M. A. Al-Anezi, G. S. Frankel, A. K. Agrawal
$0.00
$20.00
$20.00
Hydrogen Induced Cracking (HIC) and Stress Oriented Hydrogen Induced Cracking (SOHIC) tests were conducted on a conventional ASTM A516-70 pressure vessel steel exposed to H2S-containing diglycolamine (DGA) gas-sweetening environments. Baseline HIC and SOHIC tests were conducted in NACE TM-0284-A-96 solution. For the SOHIC tests, fburpoint double beam specimens were stressed to 60%, 80% or 100% of the yield strength of the steel in order to study the effect of applied stress. Test conditions included solutions containing 70 wt. % DGA and 500 ppm H2S to 0.45 or higher mole-H2S/mole-DGA and temperatures of 25, 45 and 80°C. Corrosion rates of the steel were calculated from weight loss of the HIC specimens in order to compare the severity of the test environment with the actual service environment. Cracks were characterized in terms of crack length ratio (CLR), crack thickness ratio (CTR) and crack sensitivity ratio (CSR). Results indicate that conventional ASTM A5 16-70 pressure vessel steel is not susceptible to HIC or SOHIC in various H2S containing DGA solutions at the temperatures studied. Keywords: hydrogen sulfide, hydrogen induced cracking, stress oriented hydrogen induced cracking, diglycolamine, pressure vessel steel
Hydrogen Induced Cracking (HIC) and Stress Oriented Hydrogen Induced Cracking (SOHIC) tests were conducted on a conventional ASTM A516-70 pressure vessel steel exposed to H2S-containing diglycolamine (DGA) gas-sweetening environments. Baseline HIC and SOHIC tests were conducted in NACE TM-0284-A-96 solution. For the SOHIC tests, fburpoint double beam specimens were stressed to 60%, 80% or 100% of the yield strength of the steel in order to study the effect of applied stress. Test conditions included solutions containing 70 wt. % DGA and 500 ppm H2S to 0.45 or higher mole-H2S/mole-DGA and temperatures of 25, 45 and 80°C. Corrosion rates of the steel were calculated from weight loss of the HIC specimens in order to compare the severity of the test environment with the actual service environment. Cracks were characterized in terms of crack length ratio (CLR), crack thickness ratio (CTR) and crack sensitivity ratio (CSR). Results indicate that conventional ASTM A5 16-70 pressure vessel steel is not susceptible to HIC or SOHIC in various H2S containing DGA solutions at the temperatures studied. Keywords: hydrogen sulfide, hydrogen induced cracking, stress oriented hydrogen induced cracking, diglycolamine, pressure vessel steel
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 99416 DETECTION, REPAIR, AND MITIGATION OF
Available for download

99416 DETECTION, REPAIR, AND MITIGATION OF WET H2S CRACKING: AN OVERVIEW OF RP0296

Product Number: 51300-99416-SG
ISBN: 99416 1999 CP
Author: M. W, Mucek
$20.00
Picture for 99420 NACE COMMITTEE REPORT 8X294: REVIEW
Available for download

99420 NACE COMMITTEE REPORT 8X294: REVIEW OF PUBLISHED LITERATURE ON WET H2S CRACKING

Product Number: 51300-99420-SG
ISBN: 99420 1999 CP
Author: R.D. Kane and M.S. Cayard
$20.00
Picture for 99417 OVERVIEW OF NACE INTERNATIONAL
Available for download

99417 OVERVIEW OF NACE INTERNATIONAL STANDARD RP0472

Product Number: 51300-99417-SG
ISBN: 99417 1999 CP
Author: Cathleen Shargay
$20.00