99300 HALOGEN COMPATIBLE TREATMENT PROGRAMS FOR OPEN RECIRCULATING COOLING WATER SYSTEMS

Product Number: 51300-99300-SG
ISBN: 99300 1999 CP
Author: Stephen M. Kessler, Kurt Given
$0.00
$20.00
$20.00
Stabilized phosphate cooling water programs have been exceptionally tiective and well established in the marketplace for close to twenty years. Ident.itlcat.ion of this technology allowed chromate to be eliminated from open recirculating systems, providing less toxic operating conditions. However, very good control of stabilized phosphate applications is necessary in order to ensure chrome-like corrosion and deposit control performance. Difficulties with stabilized phosphate technology have occurred when it is used along with chlorine. Elevated chlorine dosages are sometimes necessary for microbial control. When this occurs, copper induced pitting becomes a concern as does the degradation of the cooling water program itself, i.e. phosphonate reversion. New programs have been identified which maintain their component integrity in the presence of chlorine. They offer improved deposit control performance under a variety of stressed cooling water conditions by using select polymer blends, as opposed to a single polymer. They also incorporate a new azole corrosion inhibition chemistry which minimizes copper-induced pitting associated with over-chlorination. Laboratory and field experience with this technology is discussed. Keywords: cooling water, stabilized phosphate, corrosion inhibitor, deposit control, halogenation, phosphonate, azole, acrylic acid polymers, copper-induced corrosion
Stabilized phosphate cooling water programs have been exceptionally tiective and well established in the marketplace for close to twenty years. Ident.itlcat.ion of this technology allowed chromate to be eliminated from open recirculating systems, providing less toxic operating conditions. However, very good control of stabilized phosphate applications is necessary in order to ensure chrome-like corrosion and deposit control performance. Difficulties with stabilized phosphate technology have occurred when it is used along with chlorine. Elevated chlorine dosages are sometimes necessary for microbial control. When this occurs, copper induced pitting becomes a concern as does the degradation of the cooling water program itself, i.e. phosphonate reversion. New programs have been identified which maintain their component integrity in the presence of chlorine. They offer improved deposit control performance under a variety of stressed cooling water conditions by using select polymer blends, as opposed to a single polymer. They also incorporate a new azole corrosion inhibition chemistry which minimizes copper-induced pitting associated with over-chlorination. Laboratory and field experience with this technology is discussed. Keywords: cooling water, stabilized phosphate, corrosion inhibitor, deposit control, halogenation, phosphonate, azole, acrylic acid polymers, copper-induced corrosion
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 99304 ADVANCES IN ZINC FREE ALKALINE COOLING
Available for download

99304 ADVANCES IN ZINC FREE ALKALINE COOLING WATER TREATMENT

Product Number: 51300-99304-SG
ISBN: 99304 1999 CP
Author: D.A. Meiser, E. B. Smyk, B. Yang
$20.00
Picture for 99307 MINIMIZING LOCALIZED CORROSION VIA NEW
Available for download
Picture for 99343 REVIEW OF FAILURE MODES IN HOT-
Available for download

99343 REVIEW OF FAILURE MODES IN HOT-WATER BOILERS

Product Number: 51300-99343-SG
ISBN: 99343 1999 CP
Author: Harvey M. Herro
$20.00