98619 Simple Approach to Pipeline Electrical Isolation

Product Number: 51300-98619-SG
ISBN: 98619 1998 CP
Author: Bruce E. Morris, Joseph L. Pikas
$0.00
$20.00
$20.00
Isolating flanges/joints are required in cathodically protected pipeline systems to electrically isolate the pipeline from customer meter stations, pumping stations, points of ownership and other in-line sections. Typically the corrosion engineer plans and selects the areas for the installation of these devices in the piping system during planning and/or pre-construction meetings. However in practice, the actual installation of isolating flanges is left up to the engineering- construction group who may have little knowledge of the requirements to have effective electrical isolation. Field fabricated isolating flanges could be rendered ineffective by over torquing and improper alignment, inadequate coating internally and externally, improper selection of gaskets, sleeves, and washers, etc. This paper will discuss the use of high dielectric resistance materials and the construction of preassembled isolating flanges that includes coating, hydrostatic and electrical testing techniques. This approach eliminates the high costs associated in replacing damaged, leaking, or shorted flanges from the pit falls of improper techniques used during construction.
Isolating flanges/joints are required in cathodically protected pipeline systems to electrically isolate the pipeline from customer meter stations, pumping stations, points of ownership and other in-line sections. Typically the corrosion engineer plans and selects the areas for the installation of these devices in the piping system during planning and/or pre-construction meetings. However in practice, the actual installation of isolating flanges is left up to the engineering- construction group who may have little knowledge of the requirements to have effective electrical isolation. Field fabricated isolating flanges could be rendered ineffective by over torquing and improper alignment, inadequate coating internally and externally, improper selection of gaskets, sleeves, and washers, etc. This paper will discuss the use of high dielectric resistance materials and the construction of preassembled isolating flanges that includes coating, hydrostatic and electrical testing techniques. This approach eliminates the high costs associated in replacing damaged, leaking, or shorted flanges from the pit falls of improper techniques used during construction.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for Monolithic Isolation Joints: A Possible Weak Link in Pipeline Integrity
Available for download

51314-3989-Monolithic Isolation Joints: A Possible Weak Link in Pipeline Integrity

Product Number: 51314-3989-SG
ISBN: 3989 2014 CP
Author: Robert Rettew
Publication Date: 2014
$20.00