Batteries in storage which were used in electronic fuzes were found to be leaking after 5 years. The leaking battery ampules were made of copper and contained mixture of fluoboric acid and methylene bromide. The corrosion mechanism is described along with the testing/analysis required to simulate the field failures. Keywords: Power supply, battery copper ampule, fluoboric acid, methylene chloride, methylene bromide.
Batteries in storage which were used in electronic fuzes were found to be leaking after 5 years. The leaking battery ampules were made of copper and contained mixture of fluoboric acid and methylene bromide. The corrosion mechanism is described along with the testing/analysis required to simulate the field failures. Keywords: Power supply, battery copper ampule, fluoboric acid, methylene chloride, methylene bromide.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 96625 ALKALINE OXIDE CONVERSION COATINGS
Available for download

96625 ALKALINE OXIDE CONVERSION COATINGS FOR ALUMINUM ALLOYS

Product Number: 51300-96625-SG
ISBN: 96625 1996 CP
Author: R.G.Buchheit
$20.00
Picture for 96620 CORROSION DESIGN CRITERIA FOR
Available for download

96620 CORROSION DESIGN CRITERIA FOR ELECTRONICS / SIMULATORS

Product Number: 51300-96620-SG
ISBN: 96620 1996 CP
Author: Joseph Menke
$20.00
Picture for 96574 RECOVERING DISTILLED WATER AND PURE
Available for download

96574 RECOVERING DISTILLED WATER AND PURE SALT PRODUCTS FROM INDUSTRIAL WASTEWATER: THREE CASE STUDIES

Product Number: 51300-96574-SG
ISBN: 96574 1996 CP
Author: K.E. Schooley, R.S. Ludlum
$20.00