96315 MECHANICAL PROPERTIES AND FRACTURE STRENGTH OF CATHODICALLY POLARIZED PRESTRESSING WIRE

Product Number: 51300-96315-SG
ISBN: 96315 1996 CP
Author: Stanislas Kiszowski, William H. Hartt
$0.00
$20.00
$20.00
Constant extension rate testing experiments were performed upon prestressing steel wire specimens prepared from three lots of Grade 270 and one lot of Grade 250 material for the purpose of characterizing susceptibility to environmental cracking under conditions associated with cathodic protection of prestressed concrete components and structures. Smooth, notched (six different geometries) and pitted (four different geometries) specimens were tested in air and deaerated saturated Ca(OH)2-distilled water at potentials of -0.90 and -1.30 v (SCE) and strength and ductility properties characterized. Relatively low strength was recorded for steel specimens at -0.90 v from material for which the weight percent chromium was relatively high (0.24 w/o compared to 0.02 w/o). Under conditions that are likely to be most relevant to service, fracture load correlated with the amount by which the local wire cross section area was reduced, either from a notch or pit, and was independent of depth of the irregularity and of root radius to the extent to which these were addressed. In was concluded that it may be unsafe to apply catholically protection to prestressing wire, even in situations where potential is maintained in the regime where hydrogen embrittlement should not occur, Keywords: Cathodic protection, prestressing steel, prestressed concrete, hydrogen embrittlement.
Constant extension rate testing experiments were performed upon prestressing steel wire specimens prepared from three lots of Grade 270 and one lot of Grade 250 material for the purpose of characterizing susceptibility to environmental cracking under conditions associated with cathodic protection of prestressed concrete components and structures. Smooth, notched (six different geometries) and pitted (four different geometries) specimens were tested in air and deaerated saturated Ca(OH)2-distilled water at potentials of -0.90 and -1.30 v (SCE) and strength and ductility properties characterized. Relatively low strength was recorded for steel specimens at -0.90 v from material for which the weight percent chromium was relatively high (0.24 w/o compared to 0.02 w/o). Under conditions that are likely to be most relevant to service, fracture load correlated with the amount by which the local wire cross section area was reduced, either from a notch or pit, and was independent of depth of the irregularity and of root radius to the extent to which these were addressed. In was concluded that it may be unsafe to apply catholically protection to prestressing wire, even in situations where potential is maintained in the regime where hydrogen embrittlement should not occur, Keywords: Cathodic protection, prestressing steel, prestressed concrete, hydrogen embrittlement.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 96314 INFLUENCE OF CATHODIC POLARIZATION UPON BOND
Available for download

96314 INFLUENCE OF CATHODIC POLARIZATION UPON BOND STRENGTH OF PRETENSIONED TENDONS IN CONCRETE

Product Number: 51300-96314-SG
ISBN: 96314 1996 CP
Author: Emmanuel Joubert, William H. Hartt
$20.00
Picture for 96308 BOND STRENGTH OF ELECTROCHEMICALLY-
Available for download

96308 BOND STRENGTH OF ELECTROCHEMICALLY-AGED ARC-SPRAYED ZINC COATINGS ON CONCRETE

Product Number: 51300-96308-SG
ISBN: 96308 1996 CP
Author: Bernard S. Covino, Jr,, Sophie J. Bullard, Gordon R. Holcomb, Stephen D. Cramer, Galen E. McGill, Cu
$20.00
Picture for 97252 ANALYTICAL EVALUATION OF SACRIFICIAL
Available for download

97252 ANALYTICAL EVALUATION OF SACRIFICIAL ANODE CATHODIC PROTECTION SYSTEMS FOR STEEL IN CONCRETE

Product Number: 51300-97252-SG
ISBN: 97252 1997 CP
Author: William H. Hartt
$20.00