96191 A STATISTICAL APPROACH TO DESIGNING MITIGATION FOR INDUCED AC VOLTAGES

Product Number: 51300-96191-SG
ISBN: 96191 1996 CP
Author: John Dabkowski
$0.00
$20.00
$20.00
Induced voltage levels on buried pipelines collocated with overhead electric power transmission lines are usually mitigated by means of grounding the pipeline. Maximum effectiveness is obtained when grounds are placed at discrete locations along the pipeline where the peak induced voltages occur. The degree of mitigation achieved is dependent upon the local soil resistivity at these locations. On occasion it may be necessary to employ an extensive distributed grounding system, for example, a parallel buried wire connected to the pipe at periodic intervals. In this situation the a priori calculation of mitigated voltage levels is sometimes made assuming an average value for the soil resistivity. Over long distances, however, the soil resistivity generally varies as a log-normally distributed random variable. The effect of this variability upon the predicted mitigated voltage levels is examined. It is found that the predicted levels exhibit a statistical variability which precludes a precise determination of the mitigated voltage levels. Thus, post commissioning testing of the emplaced mitigation system is advisable. Keywords: ac induction, induced ac voltages, induced voltage mitigation, pipeline grounding, soiltivity measurements, resistivity measurements
Induced voltage levels on buried pipelines collocated with overhead electric power transmission lines are usually mitigated by means of grounding the pipeline. Maximum effectiveness is obtained when grounds are placed at discrete locations along the pipeline where the peak induced voltages occur. The degree of mitigation achieved is dependent upon the local soil resistivity at these locations. On occasion it may be necessary to employ an extensive distributed grounding system, for example, a parallel buried wire connected to the pipe at periodic intervals. In this situation the a priori calculation of mitigated voltage levels is sometimes made assuming an average value for the soil resistivity. Over long distances, however, the soil resistivity generally varies as a log-normally distributed random variable. The effect of this variability upon the predicted mitigated voltage levels is examined. It is found that the predicted levels exhibit a statistical variability which precludes a precise determination of the mitigated voltage levels. Thus, post commissioning testing of the emplaced mitigation system is advisable. Keywords: ac induction, induced ac voltages, induced voltage mitigation, pipeline grounding, soiltivity measurements, resistivity measurements
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 03703 METHODOLOGIES FOR AC MITIGATION
Available for download

03703 METHODOLOGIES FOR AC MITIGATION

Product Number: 51300-03703-SG
ISBN: 03703 2003 CP
Author: J. Dabkowski
$20.00
Picture for 01597 DESIGN CONSIDERATIONS FOR MITIGATION
Available for download

01597 DESIGN CONSIDERATIONS FOR MITIGATION OF INDUCED AC ON PIPELINES

Product Number: 51300-01597-SG
ISBN: 01597 2001 CP
Author: John Dabkowski, Earl L. Kirkpatrick, P.E.
$20.00
Picture for 98561 A REVIEW OF AC POWER LINE COUPLING
Available for download

98561 A REVIEW OF AC POWER LINE COUPLING UNTO BURIED PIPELINES

Product Number: 51300-98561-SG
ISBN: 98461 1998 CP
Author: John Dabkowski
$20.00