96026 CAROLINE PIPELINE FAILURE: FINDINGS ON CORROSION MECHANISMS IN WET SOUR GAS SYSTEMS CONTAINING SIGNIFICANT CO,

Product Number: 51300-96026-SG
ISBN: 96026 1996 CP
Author: Nguyen N. Bich, Kevin Goerz
$0.00
$20.00
$20.00
A leak occurred in the 5-32S flowline between Junction 1 and the South Compressor Station in the Canada Limited Caroline Complex gathering system near Sundre, Alberta, due to internal wet H2S (hydrogen sulphide) and CO2 (carbon dioxide) pitting corrosion at the bottom of the pipeline. The significant contributing factors to the extremely high pitting corrosion rate, approximately 30 mm/y (1200 mpy), are considered to be unexpectedly high amounts of chloride ions in the produced well fluids, settling of the produced water under low flow conditions, high condensate/water ratio, inadequate inhibition and pigging, and insufficient monitoring programs. Corrosion mechanisms in sour gas gathering systems with significant CO2 concentration were reviewed. Preliminary findings pointed to CO, partial pressure, not H2S, as a main corrosion rate determining factor. The steps taken to prevent similar future incidents were also reviewed. Keywords: carbon dioxide, corrosive gas, sour gas wells, inhibition, gas transmission
A leak occurred in the 5-32S flowline between Junction 1 and the South Compressor Station in the Canada Limited Caroline Complex gathering system near Sundre, Alberta, due to internal wet H2S (hydrogen sulphide) and CO2 (carbon dioxide) pitting corrosion at the bottom of the pipeline. The significant contributing factors to the extremely high pitting corrosion rate, approximately 30 mm/y (1200 mpy), are considered to be unexpectedly high amounts of chloride ions in the produced well fluids, settling of the produced water under low flow conditions, high condensate/water ratio, inadequate inhibition and pigging, and insufficient monitoring programs. Corrosion mechanisms in sour gas gathering systems with significant CO2 concentration were reviewed. Preliminary findings pointed to CO, partial pressure, not H2S, as a main corrosion rate determining factor. The steps taken to prevent similar future incidents were also reviewed. Keywords: carbon dioxide, corrosive gas, sour gas wells, inhibition, gas transmission
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 96032 C02 CORROSION IN WET GAS SYSTEMS
Available for download

96032 CO2 CORROSION IN WET GAS SYSTEMS

Product Number: 51300-96032-SG
ISBN: 96032 1996 CP
Author: P.A. Attwood, Kees van Gelder and C.D. Charnley
$20.00
Picture for 03174 CORROSION EXPERIENCES AND
Available for download

03174 CORROSION EXPERIENCES AND INHIBITION PRACTICES MANAGING WET SOUR SALTY GAS PIPELINE ENVIRONMENTS CONTAMINATED WITH ELEMENTAL SULFUR DEPOSITS

Product Number: 51300-03174-SG
ISBN: 03174 2003 CP
Author: M.R. Gregg, J. Slofstra, D. Thill, W. Sudds
$20.00
Picture for 96027 COMBINING RESEARCH AND FIELD DATA
Available for download

96027 COMBINING RESEARCH AND FIELD DATA FOR CORROSION RATE PREDICTION

Product Number: 51300-96027-SG
ISBN: 96027 1996 CP
Author: Y.M. Gunaltun
$20.00