10112 Methods, Simulations and Experiences on DC-Traction Interference on Pipeline Networks

Product Number: 51300-10112-SG
ISBN: 10112 2010 CP
Author: L. Bortels, J. Parlongue, P. J. Stehouwer, and K. Dijkstra
Publication Date: 2010
$0.00
$20.00
$20.00
The main gas operator in the Netherlands has about 12.000 Km of pipeline. Most of these pipelines are situated in congested right-of-ways (ROWs), including 1500 V DC traction systems. According to the Dutch Standards NEN EN 50162 and NEN EN 50122 it is likely that both systems interfere on each other. Looking at the field measurements one can conclude that about 50% of the pipeline network (including 120 DC-drain unit’s that are operational) is under interference of stray current.

To get a better understanding of DC-traction interference, the Company started a joint working group with the Dutch railway. This technical committee aims at a better understanding of theoretical and practical principals of DC-traction stray current. It tries to approve field procedures and to get information on what has to be done to solve CP-related problems.

In this presentation it will be demonstrated how the field measurement technique that has been designed will be used. It will be discussed how the measured data needs to be interpreted to determine the rail resistance to earth and the risk area’s for the pipelines.

Keywords: Simulation software, cathodic protection, pipeline network, DC-traction interference
The main gas operator in the Netherlands has about 12.000 Km of pipeline. Most of these pipelines are situated in congested right-of-ways (ROWs), including 1500 V DC traction systems. According to the Dutch Standards NEN EN 50162 and NEN EN 50122 it is likely that both systems interfere on each other. Looking at the field measurements one can conclude that about 50% of the pipeline network (including 120 DC-drain unit’s that are operational) is under interference of stray current.

To get a better understanding of DC-traction interference, the Company started a joint working group with the Dutch railway. This technical committee aims at a better understanding of theoretical and practical principals of DC-traction stray current. It tries to approve field procedures and to get information on what has to be done to solve CP-related problems.

In this presentation it will be demonstrated how the field measurement technique that has been designed will be used. It will be discussed how the measured data needs to be interpreted to determine the rail resistance to earth and the risk area’s for the pipelines.

Keywords: Simulation software, cathodic protection, pipeline network, DC-traction interference
Product tags
Also Purchased
Picture for 08062 Study on Pipeline Interference From Stray Current of DC Light Railway
Available for download

08062 Study on Pipeline Interference From Stray Current of DC Light Railway

Product Number: 51300-08062-SG
ISBN: 08062 2008 CP
Author: Chang Fang Wu, Lingli Liu, and Hongyuan Chen
Publication Date: 2008
$20.00