Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

10105 AC Mitigation and Cathodic Protection for a Long Regulated Pipeline

Product Number: 51300-10105-SG
ISBN: 10105 2010 CP
Author: Dale Lindemuth, P.E., Jerry Creel, Hector Hernandez, and Mike Neeley
Publication Date: 2010
$0.00
$20.00
$20.00
This paper highlights the coordinated AC mitigation and cathodic protection strategy for a 167 mile (269 km) long high-pressure interstate natural gas pipeline. Ninety-five percent of the pipeline is located adjacent and parallel to high voltage AC power transmission lines ranging to 500 kV. Analyses and computer simulations during the front-end engineering design predicted that, without suitable mitigation, steady-state AC potentials (referenced to local earth) on the pipeline would easily exceed 100 V; AC coating stress and touch potentials approaching 12,000 V were predicted during a power line to ground fault. The AC mitigation and cathodic protection designs were closely coordinated with operations personnel to assure systems that were maintenance-friendly. Corrosion control commissioning included a multi-channel AC and DC close interval potential survey protocol. The baseline data document the success of the AC mitigation and cathodic protection in safely and cost effectively controlling soil corrosion and AC interference. Long-term surveillance includes state-of-the-art remote monitoring and the use of coupon technology.

Keywords: AC interference, AC mitigation, close interval potential survey, coupon technologies
This paper highlights the coordinated AC mitigation and cathodic protection strategy for a 167 mile (269 km) long high-pressure interstate natural gas pipeline. Ninety-five percent of the pipeline is located adjacent and parallel to high voltage AC power transmission lines ranging to 500 kV. Analyses and computer simulations during the front-end engineering design predicted that, without suitable mitigation, steady-state AC potentials (referenced to local earth) on the pipeline would easily exceed 100 V; AC coating stress and touch potentials approaching 12,000 V were predicted during a power line to ground fault. The AC mitigation and cathodic protection designs were closely coordinated with operations personnel to assure systems that were maintenance-friendly. Corrosion control commissioning included a multi-channel AC and DC close interval potential survey protocol. The baseline data document the success of the AC mitigation and cathodic protection in safely and cost effectively controlling soil corrosion and AC interference. Long-term surveillance includes state-of-the-art remote monitoring and the use of coupon technology.

Keywords: AC interference, AC mitigation, close interval potential survey, coupon technologies
Product tags
Also Purchased
Picture for 03703 METHODOLOGIES FOR AC MITIGATION
Available for download

03703 METHODOLOGIES FOR AC MITIGATION

Product Number: 51300-03703-SG
ISBN: 03703 2003 CP
Author: J. Dabkowski
$20.00
Picture for 01597 DESIGN CONSIDERATIONS FOR MITIGATION
Available for download

01597 DESIGN CONSIDERATIONS FOR MITIGATION OF INDUCED AC ON PIPELINES

Product Number: 51300-01597-SG
ISBN: 01597 2001 CP
Author: John Dabkowski, Earl L. Kirkpatrick, P.E.
$20.00