10065 On-Line Monitoring of Average Coating Resistance with Off-Potential Mode T/R's-Operator Experiences

Product Number: 51300-10065-SG
ISBN: 10065 2010 CP
Author: Lars Vendelbo Nielsen and Bent Baumgarten
Publication Date: 2010
$0.00
$20.00
$20.00
Specially designed rectifiers capable of operating in off-potential mode have been operating successfully for more than two years in the Greater Copenhagen Natural Gas1 distribution system. The rectifier system is based on a conventional transformer rectifier operating in potential mode and a PLC controlled off-potential measurement and feed-back procedure. The IR drop is fed to the rectifier feed back loop hereby offsetting the conventional potential control by this (IR) amount.

The parameters resulting from the above described system include on-potential, off-potential, rectifier current, IR-drop and the average coating resistance of the pipeline. Benefits include:

• The off-potential facility has proved to effectively provide a reproducible measure of the average coating resistance enabling the operator to conduct instant investigations on cause of coating damages and to pursue any third party that might have caused coating or pipeline damage.

• The remote controlled T/R system automatically produces measurements in the silent hours (where no DC traction systems are active) as required in stray current areas thereby saving the operator for inconvenient and costly working hours.

Keywords: cathodic protection, remote monitoring, coating resistance, off-potential, third party damage
Specially designed rectifiers capable of operating in off-potential mode have been operating successfully for more than two years in the Greater Copenhagen Natural Gas1 distribution system. The rectifier system is based on a conventional transformer rectifier operating in potential mode and a PLC controlled off-potential measurement and feed-back procedure. The IR drop is fed to the rectifier feed back loop hereby offsetting the conventional potential control by this (IR) amount.

The parameters resulting from the above described system include on-potential, off-potential, rectifier current, IR-drop and the average coating resistance of the pipeline. Benefits include:

• The off-potential facility has proved to effectively provide a reproducible measure of the average coating resistance enabling the operator to conduct instant investigations on cause of coating damages and to pursue any third party that might have caused coating or pipeline damage.

• The remote controlled T/R system automatically produces measurements in the silent hours (where no DC traction systems are active) as required in stray current areas thereby saving the operator for inconvenient and costly working hours.

Keywords: cathodic protection, remote monitoring, coating resistance, off-potential, third party damage
Product tags
Also Purchased
Picture for 98679 COMPUTER MODELING OF PIPELINES
Available for download

98679 COMPUTER MODELING OF PIPELINES AND THEIR CP SYSTEMS FOR IR DROP MEASUREMENT CORRECTION

Product Number: 51300-98679-SG
ISBN: 98679 1998 CP
Author: F. Dawalibi, R. D. Southey
$20.00
Picture for 100mV Cathodic Protection Criterion-Using of "Instant-On" Potential for ICCP of new structure
Available for download

51312-01642-100mV Cathodic Protection Criterion-Using of "Instant-On" Potential for ICCP of new structure

Product Number: 51312-01642-SG
ISBN: 01642 2012 CP
Author: Javad Khosravi
Publication Date: 2012
$20.00