Search
Filters
Close

09579 Failure of Austenitic Stainless Steel Drain Piping of OCR Reactor in Atmospheric Desulphurization Unit (ARDS) of Mina Abdulla Refinery, Kuwait National Petroleum Company (KNPC)

Product Number: 51300-09579-SG
ISBN: 09579 2009 CP
Author: Mutlaq M. AL-Enezi, Faisal H. AL-Refai, Sunil V. Vipat and Anil K. Ray
Publication Date: 2009
$0.00
$20.00
$20.00
On-Stream Catalyst Replacement Reactors in the Atmospheric Residuum Desulfurization Unit (ARDS) are provided with 4? dia. X sch. 160 TP321 stainless steel (SS) piping for draining the reactor inventory during shutdowns. A total of three on-stream failures of these drain lines caused unit shutdowns and Safety, Health & Environment (SHE) hazards . Failures were in the form of extensive multi branched cracks in the parent metal/weld/heat affected zone (HAZ). Failure was the result of exposure to high concentrations of aqueous chlorides, and stress concentrations due to poor weld quality and mismatch of thickness between 90o elbows and pipe. High pressures (stress) in the system, high chloride concentration in the stagnant section of pipe, and low temperatures in the stagnant section of the pipe aggravated the situation, which resulted in typical Chloride Stress Corrosion Cracking (SCC) failures.

Keywords: Stress Corrosion Cracking, Austenitic Stainless Steel, Transgranular Cracking, ARDS, OCR, Weld Joint Mismatch, High Pressure, High Temperature
On-Stream Catalyst Replacement Reactors in the Atmospheric Residuum Desulfurization Unit (ARDS) are provided with 4? dia. X sch. 160 TP321 stainless steel (SS) piping for draining the reactor inventory during shutdowns. A total of three on-stream failures of these drain lines caused unit shutdowns and Safety, Health & Environment (SHE) hazards . Failures were in the form of extensive multi branched cracks in the parent metal/weld/heat affected zone (HAZ). Failure was the result of exposure to high concentrations of aqueous chlorides, and stress concentrations due to poor weld quality and mismatch of thickness between 90o elbows and pipe. High pressures (stress) in the system, high chloride concentration in the stagnant section of pipe, and low temperatures in the stagnant section of the pipe aggravated the situation, which resulted in typical Chloride Stress Corrosion Cracking (SCC) failures.

Keywords: Stress Corrosion Cracking, Austenitic Stainless Steel, Transgranular Cracking, ARDS, OCR, Weld Joint Mismatch, High Pressure, High Temperature
Product tags
Also Purchased
Picture for 10350 Erosion of Austenitic Stainless Steel 90° Elbows of Charge Heater Tubes
Available for download

10350 Erosion of Austenitic Stainless Steel 90° Elbows of Charge Heater Tubes in Atmospheric Residue De-Sulphurization Unit (ARDS) of Mina Abdulla Refinery

Product Number: 51300-10350-SG
ISBN: 10350 2010 CP
Author: Sunil V. Vipat, Musaed Al Arada, Mutlaq Al Enezi and Anil Kumar Ray
Publication Date: 2010
$20.00
Picture for 07113 Experiments on MIC of Steel and FRP Downhole Tubulars in West Kuwait Brines
Available for download

07113 Experiments on MIC of Steel and FRP Downhole Tubulars in West Kuwait Brines

Product Number: 51300-07113-SG
ISBN: 07113 2007 CP
Author: AbdulHameed Al-Hashem, John A. Carew, and Paula J.B. Scott
Publication Date: 2007
$20.00
Picture for 09563 CO2 Corrosion Inhibition and Oil Wetting of Carbon Steel With Ferric Corrosion Products
Available for download

09563 CO2 Corrosion Inhibition and Oil Wetting of Carbon Steel With Ferric Corrosion Products

Product Number: 51300-09563-SG
ISBN: 09563 2009 CP
Author: Egil Gulbrandsen, Martin Foss and Johan Sjoblom
Publication Date: 2009
$20.00