Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

09509 Measurement of CPC Performance Using EIS Based Coating Degradation Sensors

Product Number: 51300-09509-SG
ISBN: 09509 2009 CP
Author: Marta Andrea Jakab and Garth Tormoen
Publication Date: 2009
$0.00
$20.00
$20.00
The cost associated with maintenance and field replacement of military assets is often reduced by the application of temporary coating systems that protect the military vehicles against corrosion. The performance of these coatings can be assessed using coating degradation sensors. This paper addresses the laboratory studies of an impedance based coating degradation sensor that utilizes wireless, mote based technology. The ability of the coating degradation sensor to assess coating failures in simulated coastal environments is demonstrated. The results are compared with those of field exposure at Daytona Beach, FL. The effects of the sensor design and measurement parameters on the sensitivity of the sensor are explored. Examples of the sensor output to determine failures of corrosion preventive compounds (CPCs) in case of boldly exposed surfaces and occluded sites will be presented.

Keywords: corrosion preventive compounds, wireless sensors, electrochemical impedance
The cost associated with maintenance and field replacement of military assets is often reduced by the application of temporary coating systems that protect the military vehicles against corrosion. The performance of these coatings can be assessed using coating degradation sensors. This paper addresses the laboratory studies of an impedance based coating degradation sensor that utilizes wireless, mote based technology. The ability of the coating degradation sensor to assess coating failures in simulated coastal environments is demonstrated. The results are compared with those of field exposure at Daytona Beach, FL. The effects of the sensor design and measurement parameters on the sensitivity of the sensor are explored. Examples of the sensor output to determine failures of corrosion preventive compounds (CPCs) in case of boldly exposed surfaces and occluded sites will be presented.

Keywords: corrosion preventive compounds, wireless sensors, electrochemical impedance
Product tags
Also Purchased
Picture for 08202 Measurement of CPC Performance Using EIS Based Sensor Methods - Laboratory and Field Studies
Available for download

08202 Measurement of CPC Performance Using EIS Based Sensor Methods - Laboratory and Field Studies

Product Number: 51300-08202-SG
ISBN: 08202 2008 CP
Author: Marta Jakab, James Dante, and Garth Tormoen
Publication Date: 2008
$20.00
Picture for 00275 EIS-BASED IN-SITU SENSOR FOR THE EARLY
Available for download

00275 EIS-BASED IN-SITU SENSOR FOR THE EARLY DETECTION OF COATINGS DEGRADATION AND SUBSTRATE CORROSION

Product Number: 51300-00275-SG
ISBN: 00275 2000 CP
Author: Guy D. Davis, Chester M. Dacres, and Lorrie A. Krebs
$20.00
Picture for 00794 EIS MEASUREMENTS ON CATHODICALLY PROTECTED
Available for download

00794 EIS MEASUREMENTS ON CATHODICALLY PROTECTED STEEL IN CONCRETE

Product Number: 51300-00794-SG
ISBN: 00794 2000 CP
Author: M.A. Talavera, T. Perez and J. Genesca
$20.00