09366 Increasing Zirconium's Resistance to Stress Corrosion Cracking and Intergranular Attack in Hot Concentrated Hydrochloric Acid

Product Number: 51300-09366-SG
ISBN: 09366 2009 CP
Author: Patrick Snow
Publication Date: 2009
$0.00
$20.00
$20.00
Previous studies have shown that Zr702 Zirconium (UNS R60702) is one of the best choices for use in hot concentrated hydrochloric acid. While zirconium’s corrosion resistance far exceeds that of most metals, it is susceptible to stress corrosion cracking (SCC) and intergranular attack (IGA) under certain conditions. This paper presents results of testing in 36% HCl with the addition of 100 ppm ferric chloride at temperatures near boiling. The addition of ferric chloride is expected to increase zirconium’s susceptibility to both SCC and IGA. Various heat treatments and surface conditions will be ranked according to their effectiveness in preventing SCC and IGA in this environment.

Keywords: zirconium, Zircadyne® 702, Zr702, Zirconium Grade 702, UNS R60702, intergranular corrosion, IGA, stress corrosion cracking, SCC, pitting, hydrochloric acid, corrosion, surface treatment, heat treatment, pickling, u-bend.
Previous studies have shown that Zr702 Zirconium (UNS R60702) is one of the best choices for use in hot concentrated hydrochloric acid. While zirconium’s corrosion resistance far exceeds that of most metals, it is susceptible to stress corrosion cracking (SCC) and intergranular attack (IGA) under certain conditions. This paper presents results of testing in 36% HCl with the addition of 100 ppm ferric chloride at temperatures near boiling. The addition of ferric chloride is expected to increase zirconium’s susceptibility to both SCC and IGA. Various heat treatments and surface conditions will be ranked according to their effectiveness in preventing SCC and IGA in this environment.

Keywords: zirconium, Zircadyne® 702, Zr702, Zirconium Grade 702, UNS R60702, intergranular corrosion, IGA, stress corrosion cracking, SCC, pitting, hydrochloric acid, corrosion, surface treatment, heat treatment, pickling, u-bend.
Product tags
Also Purchased
Picture for 08185 Effects of Heat Treatment and Surface Condition on the Corrosion Resistance of Zirconium in Hy
Available for download

08185 Effects of Heat Treatment and Surface Condition on the Corrosion Resistance of Zirconium in Hydrochloric Acid

Product Number: 51300-08185-SG
ISBN: 08185 2008 CP
Author: Patrick Snow, Steve Sparkowich, and Mike Bozzello
Publication Date: 2008
$20.00
Picture for 00572 HYDROCHLORIC ACID AND WATER PERMEABILITY
Available for download

00572 HYDROCHLORIC ACID AND WATER PERMEABILITY IN FLUOROPOLYMER TUBES

Product Number: 51300-00572-SG
ISBN: 00572 2000 CP
Author: Maria Conde and Claes Taxen
$20.00
Picture for 04430 Effect of Ferric Ions on the Corrosion
Available for download

04430 Effect of Ferric Ions on the Corrosion Performance of Nickel Alloys in Hydrochloric Acid Solutions

Product Number: 51300-04430-SG
ISBN: 04430 2004 CP
Author: Nacera S. Meck, Paul Crook, and Dwaine L. Klarstrom, Haynes International; Raul B. Rebak, Lawrence L
$20.00