Field observations and laboratory test results for several different fire sprinkler failure investigations conducted in the past several years in a variety of locations across the US. Field experience with assessment data, basis for diagnosis, mitigation and rehabilitation recommendations to prevent recurrence are presented.
Microbiologically Influenced Corrosion (MIC) has been implicated as the root-cause for the corrosion failure of a large number of wet, dry, and pre-action fire sprinkler systems, often resulting in costly repairs and litigation. This paper presents field observations and laboratory test results for several different fire sprinkler failure investigations conducted over the course of the past several years in a variety of locations across the US. Field experience with assessment data, basis for diagnosis, mitigation and rehabilitation recommendations to prevent recurrence are presented. Aggregated results of laboratory microbiological culturing of deposit samples collected from affected sprinkler systems are presented and discussed. Conclusions drawn from these results regarding the part that MIC plays in the corrosion failure of the various types of sprinklers systems are presented and discussed.
Keywords: MIC, sprinkler systems, field tests, lab tests, corrosion failure
We are unable to complete this action. Please try again at a later time.
If this error continues to occur, please contact AMPP Customer Support for assistance.
Use this error code for reference:
Please login to use Standards Credits*
* AMPP Members receive Standards Credits in order to redeem eligible Standards and Reports in the Store
You are not a Member.
AMPP Members enjoy many benefits, including Standards Credits which can be used to redeem eligible Standards and Reports in the Store.
You can visit the Membership Page to learn about the benefits of membership.
You have previously purchased this item.
Go to Downloadable Products in your AMPP Store profile to find this item.
You do not have sufficient Standards Credits to claim this item.
Click on 'ADD TO CART' to purchase this item.
Your Standards Credit(s)
1
Remaining Credits
0
Please review your transaction.
Click on 'REDEEM' to use your Standards Credits to claim this item.
You have successfully redeemed:
Go to Downloadable Products in your AMPP Store Profile to find and download this item.
Ccase histories of four fire protection systems where corrosion resulted in premature discharge/leakage causing significant property damage or facilities downtime. Tuberculation of galvanized piping. Two cases of dealloying (dezincification) corrosion of brass sprinkler heads. Microbiologically induced corrosion (MIC) corrosion.